3-3. System Settings

3-3-1. Tally System Setting

This unit supports red tally and green tally systems, and also supports contact supply and power voltage
supply (24 V/TTL). Set the switches on the SY-364 board according to the tally system to be used.
Switch
Contact supply (factory setting)
24 V supply
5 V supply

3-3-2. Camera Number Setting

Set the camera number with N03:CCU NO of the NETWORK SETTINGS menu.
HXCU-100
L
K
J
H
G
F
SY-364 BOARD (SIDE A)
Red tally
S730
S733
CONTACT
POWER
POWER
POWER
TTL
9
8
7
6
5
4
3
2
1
E
D
C
B
A
Green tally
S731
CONTACT
POWER
POWER
S734
POWER
TTL
3-7 (E)