This unit can display the status of this unit and entire system on the video monitor connected to the PIX
connector to check and change settings
4-1. Preparations
4-1-1. Starting/Exiting the Maintenance Mode
Starting
1. When the status screen or menu screen is displayed, hide the screen.
. When the status screen is displayed, turn the DISP/MENU lever to the DISP side once.
. When the menu screen is displayed, turn the DISP/MENU lever to the MENU side once.
2. While pressing the CONTROL knob, turn the CANCEL/ENTER lever quickly to the ENTER side twice.
3. Turn the DISP/MENU lever to the MENU side within two seconds.
DISP/MENU lever
CANCEL/ENTER lever
CONTROL knob
(Rotary encoder)
4. Check that the following screen appears. If it does not appear, repeat steps 1 to 3.
Exiting
1. When the status screen or menu screen is displayed, hide the screen.
2. Turn the CANCEL/ENTER lever quickly to the CANCEL side twice.
Changing Setting Values
To enter:
Press the CONTROL knob.
To cancel:
Turn the CANCEL/ENTER lever to the CANCEL side before pressing the CONTROL
knob. The setting of the selected item is restored.
To suspend: Turn the DISP/MENU lever to the MENU. The menu disappears.
To restart the setting operation, turn the DISP/MENU lever again to the MENU side.
4-1-2. Memory Stick
The following types of Memory Stick are available for this unit.
. Memory Stick
. Memory Stick PRO (Up to 2 GB)
HXCU-100
Section 4
Maintenance Mode
4-1 (E)