NEUTRAL SWITCH
Inspect continuity of neutral switch.
09930-99320 : Digital tester
Tester range :
Neutral switch in remo-con box
1. Disconnect neutral switch lead wires in remo-con box.
2. Inspect continuity between switch Brown lead wires while
operating remo-con handle.
Shift position
Neutral
Forward
Reverse
If out of specification, replace neutral switch.
Neutral switch on cylinder block
1. Disconnect neutral switch lead wire connector.
2. Inspect continuity between Yellow/Green and Brown lead
wires while operating remo-con handle.
Shift position
Neutral
Forward
Reverse
If out of specification :
• 1st Check switch position adjustment, readjust if necessary.
• 2nd Replace neutral switch.
NOTE:
After installing neutral switch, check for proper correct function
by operating remo-con handle.
(Continuity)
Continuity
Yes
No
No
Continuity
Yes
No
No
ELECTRICAL
REVERSE
Br
Br
Neutral switch
Clutch
lever
Reverse
Forward
Neutral
4-11
FORWARD
Br Y/G