1F – 394IENGINE CONTROLS
EXHAUST GAS RECIRCULATION
VALVE
Removal Procedure
1.
Disconnect the negative battery cable.
2.
Disconnect the Exhaust Gas Recirculation (EGR)
valve electrical connector.
3.
Remove the EGR valve retaining bolts.
4.
Remove the EGR valve from the Electronic Ignition
(EI) system ignition coil adapter.
Installation Procedure
1.
Clean the EI system ignition coil adapter mating
sur–face.
2.
Install a new EGR valve gasket.
3.
Install the EGR valve with the bolts.
Tighten
Tighten the exhaust gas recirculation valve retaining
bolts to 15 lb–ft (20 NSm).
4.
Connect the EGR valve electrical connector.
5.
Connect the negative battery cable.
G SENSOR
Removal Procedure
1.
Disconnect the negative battery cable.
2.
Disconnect the G sensor electrical connector and
re–move the G sensor.