BATTERY TYPE SETTING (WET OR GEL) (For For Adfinity

Set the electronic board of the machine and of the battery charger according to the type of batteries installed (WET or GEL) as
shown below:
Machine setting
1.
Press the switch (71) or (73) and pay attention to the following in the very first seconds of machine operation:
If the green warning light (81a) is flashing, the machine is set to GEL.
If the red warning light (81c) is flashing, the machine is set to WET.
2.
If the setting is to be changed, perform the following procedure.
3.
Make sure that the switches (71) and (73) are turned off.
4.
Press and hold the switches (71) and (73) at the same time.
5.
Release the switches (71) and (73) at least 8 seconds after starting the machine.
6.
Within three seconds, press the switch (73) again for a few seconds and check that the warning light for the required
setting is flashing (as shown in step 1).
Battery charger setting
7.
Remove the battery charger data inspection window screws (A).
8.
Remove the window (B).
9.
Turn the battery charger selector (C) to WET position for lead batteries, or to GEL position for gel batteries.
10.
Install the window (B) and tighten the screws (A).
BATTERY TYPE SETTING (WET OR GEL) (For Adfinity
Set the electronic board of the machine and of the battery charger according to the type of batteries installed (WET or GEL) as
shown below:
Machine setting
1.
Turn the ignition key (80) to "I" position and pay attention to the following in the very first seconds of machine operation:
If the green warning light (81a) is flashing, the machine is set to GEL.
If the red warning light (81c) is flashing, the machine is set to WET.
2.
If the setting is to be changed, perform the following procedure.
3.
Turn off the machine by turning the ignition key (80) to "0".
4.
Press and hold the switches (71) and (73) at the same time, then turn the ignition key (80) to "I".
5.
Release the switches (71) and (73) at least 8 seconds after starting the machine.
6.
Within three seconds, press the switch (73) again for a few seconds and check that the warning light for the required
setting is flashing (as shown in step 1).
Battery charger setting
7.
Remove the battery charger data inspection window screws (A).
8.
Remove the window (B).
9.
Turn the battery charger selector (C) to WET position for lead batteries, or to GEL position for gel batteries.
10.
Install the window (B) and tighten the screws (A).