DRIVE SYSTEM MOTOR-DIFFERENTIAL DISASSEMBLY/ASSEMBLY (Adfinity
C, X 24 D)
Disassembly
1.
If the tank (21) and/or (20) contains recovery water:
Drive the machine to the appointed disposal area.
Turn the ignition key (80) to "0".
Empty the recovery water tank (21) with the hose (16).
Empty the solution/clean water tank (20) with the hose (17).
2.
Remove the squeegee (see the procedure in the relevant paragraph).
3.
Remove the batteries (see the procedure in the relevant paragraph).
4.
Prepare an hoisting system (A) on which the machine is to be laid on one side. Place a panel (B) on the hoisting system to
avoid damaging the machine.
5.
With the help of an assistant, tilt the machine on one side and lay it on the panel (B).
6.
Remove the screws (C), then remove the wheels (D) and recover the keys (E).
7.
Remove the screws (F) on both sides.
8.
Disconnect the connectors (G) of the drive system motor.
9.
If necessary, remove the spacers (I) and the retaining rings.
10.
Remove the motor-differential (J).
Assembly
11.
Assemble the components in the reverse order of disassembly.
D
C
Adfinity
E
F
F
I
A
17 ST, 20 ST, 20 D, X 20 D, X 20 C, X 24 D
TM
SERVICE MANUAL
G
E
J
F