Detergent Tank Cleaning; Tm .X.20.D,.X.20.C,.X.24.D); Axp Draining - Advance acoustic Adfinity 17ST Pressure Washer

Axp floor machine
Hide thumbs Also See for Adfinity 17ST:
Table of Contents

Advertisement

DETERGENT TANK CLEANING (For Adfinity
1.
Drive the machine to the appointed detergent disposal area.
2.
Turn the ignition key (80) to "0".
3.
Open the cover (22) and check that the recovery water tank (21) is empty, otherwise empty it with the drain hose (16).
Close the cover (22).
4.
Grasp the handle (41) and carefully lift the tank (40).
5.
Unscrew the union and remove the hose (48) from the tank (45).
6.
Remove the tank (45) by releasing it from the fasteners.
7.
Unscrew the plug (A) and wash the detergent tank (B) in the appointed detergent disposal area. If necessary, remove the
supply hose (C) and clean it, especially in area of the vacuum end pipe (D). Install the supply hose (C).
8.
Check that the plug vent hole (E) is not clogged, by driving in air and checking if it comes out from the outer hole (F). If
necessary clean the hole with compressed air. Install the plug (A).
9.
Install the tank (45) and connect it to the hose (48).
10.
When the detergent tank and the supply hose have been drained, the AXP must be drained too (see the procedure in the
following paragraph).
AXP DRAINING (For Adfinity
1.
Clean the detergent tank, then remove the detergent remained in the hoses and in the pump.
2.
Grasp the handle (41) and carefully lower the tank (40).
3.
Turn on the machine by turning the ignition key (80) to "I".
4.
Turn on the AXP by pressing the switch (77). Check that the switch warning light (78) turns on.
5.
Press the switches (77) and (82a) at the same time, until the switch warning light (78) starts flashing (after about 5
seconds).
6.
Release the switches and wait for the warning light (78) to stop flashing and for the vacuum system to turn on.
7.
Collect the detergent remained on the floor.
8.
Turn the ignition key (80) to "0".
9.
Grasp the handle (41) and carefully lift the tank (40), then check that the hose (48) is empty, otherwise perform steps 3 to 9
again.
10.
NOTE
The draining cycle lasts about 30 seconds, then the vacuum function automatically turns on, which allows to
remove the detergent remained.
The draining cycle can also be performed with the detergent tank (45) full of water, thus cleaning the system
thoroughly.
It is advisable to perform the draining cycle when the AXP is really dirty/encrusted because the machine has
not been used/cleaned for a long time.
The draining cycle can be performed also to quickly fill the detergent supply hose when the tank (45) is full
but the system is still empty.
If necessary, the draining cycle can be repeatedly performed.
Adfinity
E
X 20 D - X 20 C - X 24 D)
TM
17 ST, 20 ST, 20 D, X 20 D, X 20 C, X 24 D
TM
SERVICE MANUAL
X 20 D - X 20 C - X 24 D)
TM
F
9096982000(1)2007-02
ENGLISH
C
A
D
B
AXP
S301525A
19

Advertisement

Table of Contents
loading