1 Introduction

This manual provides installation and programming information for the PC1404 four-zone panel security system.

1.1 Compatibility Requirements

The PC1404 product is the central component of the four-zone security system. Interaction with associated system devices is hardwired,
which follows DSC keybus standards. Communications with the central station may be achieved by a hardwired phone line. DLS may
also be remotely connected to the panel via phone line or locally connected via the PC-Link header. Shown below are the supported and
unsupported modules for the PC1404.
Note: All necessary information required to meet UL listing requirements is included in this document.
PC1404RKZ Keypad*
PK5500/PK5501/PK5508/PK5516 Keypads*
LCD5511 Fixed Message LCD Keypad*
LED5511 8-Zone LED Keypad*
PC1555RKZ 8-Zone LED Keypad*
PC5200 Power Supply*
PC5204 Power Supply with 4 PGMs*
PC5208 Low Current PGM Module*
PC5601 LED Status Module
TL300 T-Link TL300 IP Alarm Communicator*
GS3060 GPRS Universal Cellular Alarm Communicator*
3G3070 HSPA (3G) Universal Cellular Alarm Communicator*
GS3105/3125-K & BA Wireless Alarm Communicator
*UL/ULC-listed devices.
Note:
For UL/ULC-listed installations, use only UL/ULC-listed devices.
Note:
For SIA CP-01: 2010 compliant installations, the minimum required components are: PC1404 Control Panel and PC1404RKZ
keypad. Optional components that can be used with the system are: PK55XX series keypad. These keypads can only be used for SIA
CP-01: 2010 Compliant installations if the emergency keys are not enabled.
Module
PC5100 2-wire interface
RFK55XX Keypad
RF5132-433 Wireless Receiver
RF5108-433 Wireless Receiver
PC5108 Zone Expander
PC5320 Zone Expander
PC5950 Audio Module
PC5904 Large Audio Station
PC5921 Audio Station
PC5961, PC5962 Small Audio
Station
PTK5507 Touchscreen keypad

1.2 Product Specifications

Control and Indicating Equipment Specifications
Features
• Supports zone doubling — supervised and distinguishable
• NC/Single/Double EOL support
Module
PC5964 Large Audio Station
PC5401 RS232 Module
PC5400 Printer + DVACS
Escort 5580 Telephone
Interface
TL260 Series Communicators
GS2060
Series
Wireless
Alarm Communicator
TL250 Communicator
TL150 Communicator
IT100 Integration Module
IT120 Integration Module
Current Draw, mA
120
125
85
100
85
20
20
20
30
360
120
120
250 (excluding outputs)
4-Wire Smoke Detectors
FSA-410x
FSA-410xT
FSA-410xS
FSA-410xST
FSA-410xLST
FSA-410xR
FSA-410xRT
FSA-410xRS
FSA-410xRST
FSA-410xLRST
Note:
For model numbers above, x = A (ULC); x = B (UL); x = C (CE)
1 Introduction
Software Versions
1.0
1.0, 1.1, 1.2, 1.3
1.0
1.0
2.0
2.0
2.0
1.0
1.0
1.2-1.5
3.1, 3.2
3.5
3.0
2-Wire Smoke Detectors
FSA-210x
FSA-210xT
FSA-210xS
FSA-210xST
FSA-210xLST
FSA-210xR
FSA-210xRT
FSA-210xRS
FSA-210xRST
FSA-210xLRST
1