DSC PowerSeries PC1404 V1.1 Installation Manual page 18

Dsc power series security systems installation guide
Table of Contents

Advertisement

[
] Commands
*
The following is a list of the [
[
][1]
,
[
][2]
,
[
][3]
,
[
][4]
,
[
][5][Master/Supervisory Code]
,
[
][6][Master/Supervisory Code]
,
[
][7][x]
,
[
][8][Installer Code]
,
[
][9][User Code]
,
[
][0]
,
[
][1] Bypassing and Activating Stay/Away and Night Zones
*
LED Keypad
Press [
][1] to enter the bypass mode. If the Code Required for the Bypass option is enabled, enter a valid user code. The Bypass light
,
will flash. The keypad will turn ON the corresponding zone light to indicate a zone is bypassed. To bypass or unbypass a zone, enter the
2-digit zone number. Once the correct zones are bypassed, press [#] to exit. The Bypass light will be ON if any zones are manually
bypassed.
LCD Keypad
Press [
][1] to enter the bypass mode. If the Code Required for the Bypass option is enabled, enter a valid user code. The keypad will
,
display 'Scroll to View Zones'. The keypad will display the programmed zone labels for the zones and include the letter 'O' in the bot-
tom right corner if the zone is violated, or the letter 'B' if the zone is bypassed. Scroll to the appropriate zone and press the [
change the bypass status (or enter the 2-digit zone number). Once the correct zones are bypassed, press [#] to exit.
Additional Bypass Commands:
Bypass Recall:
Press [99]. The keypad will recall the last group of zones that were bypassed.
Clear Bypass:
Press [00]. The keypad will clear the bypass on all zones.
Save Bypass:
Press [95]. The keypad will save which zones are manually bypassed.
Recall Save:
Press [91]. The keypad will recall the bypassed zones that were saved.
i
Hold-up Zones cannot be assigned to bypass groups.
[
][1] Activate Auto-Bypassed Stay/Away and Night Zones
*
When the system is armed in the Stay mode by (a) arming and not exiting through a delay zone during the exit delay; or (b) pressing a
function key programmed for Stay Arm or Arming Without Entry Delay [
zones are automatically bypassed. This [
the system zones to fully or "Night" arm the system. Once this command is executed, all Stay/Away type zones will become active after
the programmed Exit Delay time, making the system armed in Night or Away mode. When the system is armed in the Away or Night
mode, if enabled by the installer, this [
armed in Stay mode. Night or Away mode is determined by whether there is a Night zone programmed on the system.
Note: Although there is an exit delay timer running, it is only an arming delay for the Stay/Away zones, and not a true exit delay where
all non-24 hour zone types can be opened and closed for the purpose of exiting. Any zone type that is not a Stay/Away zone type will
start its alarm sequence if violated during this "exit delay". Users should press
[
][2]Trouble Display
*
The panel continuously monitors a number of possible trouble conditions. If one of these conditions occurs, the keypad "Trouble" indi-
cator will light and the audible indication will sound, two short beeps every 10 seconds (except AC failure). When the [#] key is pressed
the audible indication will stop but the trouble is not cleared. Trouble conditions are logged to the Event Buffer and most troubles can
also be transmitted to the monitoring station.
To view troubles, press [
] then [2]. The "Zone" lights or LCD text display the trouble conditions 1-8.
,
Troubles 1, 5, and 6 can be expanded for more details by pressing the corresponding [1], [5], or [6] key.
Press [#] to return to the "Ready" mode. There is no Trouble memory. The Event Buffer can be used to achieve this function.
] commands available and a description of each:
,
Bypass (disarmed state)/Reactivate Stay/Away and Night Zones (armed state)
Display Trouble Conditions
Display Alarm Memory
Door Chime Enable/Disable
User Code Programming
User Functions
Command Functions 1–4
Installer Programming
No-Entry Arming
Quick Arm (disarmed state)/Quick Exit (armed state)
] [1] command is used to remove the automatic bypass from the Stay/Away zones to fully arm
,
][1] command will bypass all of the "Stay/Away" type zones immediately, making the system
,
][9], the zones programmed as "Stay/Away" or "Night" type
,
0 next to start a Quick Exit Delay to exit the premises.
,
3 Keypad Commands
] key to
,
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents