][6] – User Functions
*
To access the User Functions section, when disarmed, press [
tions described below by pressing the corresponding number or scrolling to the desired option then pressing [
[1]
Program Time and Date: Enter the time and date using the following format [HH:MM] [MM/DD/YY]. Program the time
using military standard (e.g., 8:00 pm = 20:00 hours). Valid entries for the Hour are 00-23. Valid entries for the Minute are
00-59.
[2]
Auto-Arm Control: Pressing [2] while in the User Function menu will enable (3 beeps) or disable (one long beep) the Auto-
Arm feature. With this feature enabled, the panel will automatically arm in the Away mode (Stay Away zones active) at the
same time each day. The Auto-Arm time is programmed with the [*][6][Master Code][3] command.
Note: Keypads are required if Auto-Arm is to be used.
[[3]]
Auto-Arm Time: The system can be programmed to arm at the same time each day. Upon entry of this section, enter 4 digits
for the 24 Hour Auto-Arm time. At the selected Auto-Arm time, the Keypad Buzzers will sound for the programmed time in
Section [199] to warn that an Auto-Arm is in progress. The bell can also be programmed to squawk once every 10 seconds
during this warning period. When the warning period is complete, the system will arm with no exit delay and in the Away
Mode. Auto-Arming can be cancelled or postponed only by entering a valid access code during the programmed warning
period. When the code has been entered, the warning will be silenced and Auto-Arming will be canceled or postponed,
depending on the Programming of Section [175]. Auto-Arming will be attempted at the same time the next day. Whenever
the Auto-Arming process is cancelled or postponed, the Auto-Arm Cancellation Reporting Code will be transmitted (if pro-
grammed).
The Auto-Arm Cancellation will be transmitted if arming is inhibited by one of the following:
• AC/DC Inhibit Arm
• Latching System Tampers
• Zone Expander Supervisory Fault.
PC1404 only supports one entry of Auto-Arm Time programming, which means the programmed time shall be used for
every day auto arm.
[4]
System Test: The system's Bell Output (2 sec), Keypad Lights and Communicator are tested. This test will also measure the
panel's standby battery. The system activates the siren output on medium volume for 2 seconds followed by full volume
alarm for 2 seconds. All display lights and LCD pixels turn on. When the System Test event is successfully received at the
monitoring station, the keypad will sound ringback, a series of 8 beeps.
[5]
System Serv/DLS: If enabled, this opens a window where incoming rings on the phone line are detected by the panel. This
window remains open for 6 hours. After the window has expired, DLS access will not be permitted.
[6]
User Call-up: If enabled by the installer, when this command is executed, the panel will make 1 attempt to call the down-
loading computer. The downloading computer must be waiting for the panel to call before downloading can be performed.
[7]-[0]
For Future Use

Additional Keypad Functions

The following additional keypad functions are available:
Event Buffer:
Brightness Control:
Contrast Control:
Buzzer Control:
[
][7] – Command Outputs
*
When armed or disarmed, press [*][7] followed by the command output number 1 to 4. When any command output is activated, three
acknowledgement beeps are heard. The system can be configured to require a valid access code to activate a command output.
[
][8] – Installer Programming
*
When disarmed, press [
][8][Installer Code] to enter Installer Programming. Installer Programming allows the installer to program all
,
system functions. Refer to Section 4.1 Installer Programming for details. The PC1404 v1.1 is completely programmable from any sys-
tem keypad using this command.
Note: Three-digit entries are required for section entry. When an error is made in attempting to enter a section number, [#] can be
pressed. If [#] is the first digit pressed, however, the keypad will return to the base menu.
Note: Once inside Installer Programming, the keypad will remain there for 20 minutes after the last keypress.
Note: All system events that occur while in Installer Programming will be logged to the Event Buffer and printed on the system printer;
however, these events will not be transmitted.
Note: When viewing data in sections with an LCD keypad, use the [<] and [>] keys to scroll. If using an LED keypad, press the [F] key
to scroll.
[
][9][User Code] – No-Entry Arming
*
When disarmed, entering [*][9] or pressing a function key programmed for No Entry Arm before entering an access code arms the
panel without any entry delay on the perimeter delay zones and bypasses zones that are defined as "Stay Away". This command is used
to arm the system while at home. When the system is armed in this mode, the "Armed" light will be ON flashing and the bypass light
will be on to indicate the "Stay Away" zones are bypassed. Once the panel is armed in this mode, using [*][1] will remove the bypass
from the "Stay Away" zones if they were NOT manually bypassed. The [*][1] command used here only removes the bypass from zones
14
][6] followed by the master or supervisor code. Select one of the func-
,
View the 128-event panel buffer
Adjust the display backlighting level for optimal viewing
Adjust the display contrast level for optimal viewing
Adjust the keypad buzzer tone for optimal sound
].
,