SIA False Alarm Reduction Installations
Call Waiting Cancel (Section [382], Option 4) feature on a non-Call Waiting line will prevent successful communication to the supervising station.
Programming at installation may be subordinate to other UL requirements for the intended application.
Cross zones have the ability to individually protect the intended area (e.g. motion detectors which overlap).
Cross zoning is not recommended for line security Installations nor is to be implemented on exit/entry zones.
There is a communication delay of 30 seconds in this control panel. It can be removed, or it can be increased up to 45 seconds at the option of the end user by consulting with
the installer.
Do not duplicate any reporting codes. This applies for all communication formats other than SIA or CID sending automatic programmed reporting codes.
The security system shall be installed with the sounding device activated and the communicator enabled for transmission using SIA or CID format.
Exit Time
Access to Entry and Exit delays and Bell Time Out for the system
[005], 3rd entry
Exit Time Restart
Enables the exit delay restart feature
[018], Option 7 ON
Auto Stay Arm on
Function Key: Stay Arming. All Stay/Away type zones (05, 06, 32) will be auto-
Un-vacated Premises
matically bypassed
[001] Zone type 05, 06, 32
Entry delay(s)
Access to Entry and Exit delays and Bell Time Out for the system
[005], 1st and 2nd entry
Note: Combined Entry delay and Communications Delay (Abort Window) shall
not exceed 60s
Abort Window
Access to zone attributes, i.e, swinger shutdown, transmission delay and cross
for Non-Fire zones
zone. Individual zones attribute bit 7 (Transmission delay) is by default ON
[101]-[108] bit 7 ON
Abort Window Time - for
Access to the programmable delay before communicating alarms
Non-Fire zones
Note: Combined Entry delay and Communications Delay (Abort Window) shall
[377], 4th entry
not exceed 60s
Abort Annunciation
Enables the "Communication Cancelled" message display on keypad
[382], Option 3 ON
Cancel Annunciation
Access to the reporting code for Alarm Cancelled
[328], 8th entry
Cancel Window
When an access code is entered during the cancel window, a Communications
[377], 10th entry
Cancelled reporting code is sent.
Duress Feature
Do not derive code from an existing Master/User code (e.g., Master code is 1234,
[*][5] Master Code
the duress code should not be 1233 or 1235)
Option 2 ON
Cross Zoning
This option enables Cross Zoning for entire system. Individual zones can be
[018] Option 6
enabled for Cross zoning via Zone attribute bit 8 in sections [101]-[108].
[101]-[108] bit 8 OFF
Cross Zone Timer
Access to the programmable Cross Zone timer
[176]
Swinger Shutdown for Alarms
Access to the swinger shutdown limit for zone alarms.
[377] 1st entry
Swinger Shutdown Enable
Access to zone attributes, i.e., swinger shutdown, transmission delay and cross
[101] - [108] bit 6 ON
zone. Individual zones attribute bit 6 (Swinger shutdown enabled) is by default ON
24-Hr. Auto-verified Fire
Access to 24-Hr. Auto-verified Fire
[001] Zone type 29
Call Waiting Cancel Dial
Access to the dialing sequence used to disable call waiting
String
[304], [382], Option 4 OFF
System Test:
The system activates all keypad sounders, bells or sirens for 2 seconds and all keypad lights turn on.
[*][6] Master Code, Option 4
Refer to the User Manual (part no. 29008014).
Alarm Communications
Enables communication of zone alarms while Walk Test is active.
During Walk Test
[382] Option 2
Walk Test End and Begin
Access to the reporting codes for Walk Test Begin and Walk Test End.
Reporting Codes
st
nd
[348], 1
and 2
Entries
Appendix C: Regulatory Approvals Information
Range:45- 255 seconds
Default: 60 sec.
Default: Enabled
If no exit after full arm
Default: Enabled
Range: 30 sec. to 4 min.
Default: 30 sees
May be disabled
by zone or zone type
Default: Enabled
Range: 20 - 45 sec.
Default: 30 sees
Annunciate that no
alarm was transmitted
Default: Enabled
Annunciate that a
Cancel was transmitted
Default: Enabled
Range: 005-255 min.
Default: 000
No 1+/- derivative of another
user code. No duplicates with
other user codes
Default: disabled
Programming required
Default: Disabled
May program
Range: 001-255 sec./min.
Default: 60 seconds
For all non-fire zones
shut down at 1 to 6 trips
Default: 2 trips
For non-police
response zones
Default: Enabled
Activates if a restore is not
received within the specified
time
Default: Disabled
Dependant on user phone line
Default: disabled
Required
(programmable)
Required
Required
Required
(programmable)
Required
Required
(programmable)
Required
Required
Required
Allowed
Required
Allowed
Required
(programmable)
Allowed
Required
Required

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents