Appendix E: Australian Addendum - DSC PowerSeries PC1404 V1.1 Installation Manual

Dsc power series security systems installation guide
Table of Contents

Advertisement

PC1404

Appendix E: Australian Addendum

The following are programming defaults for Australia that differ from the standard defaults in this manual:
2.2 AC Terminals (pg. 3)
For Australia, use the following plug-in Transformer: energy-efficient, input 230-240VAC/50Hz, output 16VAC 1.5A, 1.8m 2-wire output
lead; Tyco PN 88014330.
2.2 Telephone Line Wiring (pg. 4)
For Australia, wire the incoming and outgoing lines to the connection terminals of an appropriate, locally approved, telco connection out-
let.
Section
Pg Description
[005]
17
System Times
Subsect. [01]
[005]
17
System Times
Subsect. [09]
[009]
17
Main Board PGM Output Programming
[013]
18
First System Options
[017]
19
Fifth System Options
[018]
19
Sixth System Options
[023]
19
Tenth System Options
[101]-[108]
20
Zone Attributes Defaults
[168]
21
Daylight Savings Time Begins
[169]
21
Daylight Savings Time Ends
[170]
21
PGM Output Timer
[320]
and
22 Alarm (Restore) Reporting Codes,
[324]
Zones 01-08
[328]
22
Miscellaneous Alarm Reporting Codes
[329]
23
Priority Alarm and Restore Reporting
Codes
[330]-[334]
23
Tamper
Zones 01-08
[338]
23
Miscellaneous Tamper Reporting Codes
(Restore)
Reporting
Codes,
Defaults
Option
Exit Delay
Bell Time-out (BTO)
Onboard PGM 1 Type
Option 3, Panel Shows all Troubles while Armed/
Panel Shows only Fire Troubles while Armed
Option 6, Daylight Savings Time Enabled/Daylight Savings
Time Disabled
Option 7, Exit Delay Restart Enabled/Exit Delay Restart
Disabled
Option 5, Switching from Away to Stay Disabled/Away to
Stay Toggle Option Permitted
01-02, Attribute 5 (Force Arming)
07-11, Attribute 6 (Swinger Shutdown)
13-17, Attribute 6 (Swinger Shutdown)
19-21, Attribute 6 (Swinger Shutdown)
26 24-Hr. Non-Alarm, Attribute 6 (Swinger Shutdown)
Month
Week
Month
Week
Duress Alarm
Opening after Alarm
Recent Closing
Cross Zone/Police Code Alarm
Burglary Not Verified
Alarm Cancelled
Keypad [F] Fire Alarm
Keypad [A] Auxiliary Alarm
Keypad [P] Panic Alarm
Auxiliary Input Alarm
Keypad [F] Fire Restore
Keypad [A] Auxiliary Restore
Keypad [P] Panic Restore
Auxiliary Input Restore
General System Tamper/Restore
Keypad Lockout
Australian
Default
060
005
03
OFF
ON
ON
ON
ON
ON
ON
ON
ON
010
005
003
005
002
3A
21
58
59
4A
78
A6
1A
AA
2A
4A
1A
AA
2A
4A
44
45
61

Hide quick links: