Appendix A: Reporting Code Formats - DSC PowerSeries PC1404 V1.1 Installation Manual

Dsc power series security systems installation guide
Table of Contents

Advertisement

Appendix A: Reporting Code Formats

The following tables contain Contact ID and Automatic SIA format reporting codes. See Programming Sections [320]-[348] for Report-
ing Codes.
The first digit (in parentheses) is automatically sent by the control. The second two digits are programmed to indicate specific informa-
tion about the signal. For example, if zone 1 is an entry/exit point, you could program the event code as [34]. The central station would
receive the following:
*BURG - ENTRY/EXIT - 1 where the "1" indicates which zone went into alarm.
The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication Standard-
October 1997. This format will send the Account Code along with its data transmission. The transmission will look similar to the fol-
lowing at the receiver:
Note: A system event will use the Area Identifier ri00.
N = New Event
Table 1: Reporting Codes
[320]
Zone Alarms
[324]
Zone Restores
[328]
Duress Alarm
[328]
Opening After Alarm
[328]
Recent Closing
[328]
Zone Expander Supervi-
sory Alarm/Rest.
[328]
Cross Zone (Police Code)
Alarm
[328]
Alarm Cancelled
[329]
[F] Key Alarm/Rest.
[329]
[A] Key Alarm/Rest.
[329]
[P] Key Alarm/Rest.
[329]
Auxiliary Input Alarm/Rest. Option#23-24: a panic button wired to PGM 2 is pressed/
[330], [334] Zone Tamper/Restore
[338]
General System Tamper/
Rest.
[338]
Keypad Lockout
[339-341],
Closings
[601]
[341]
Automatic Zone Bypass
[341]
Partial Closing
[341]
Special Closing
[341]
Late to Close
[341]
Exit Fault
[342-344],
Openings
[605]
[344]
Special Opening
[345]-[346] Battery Trouble/Rest.
N ri1= BA 01
ri1 = Partition /Area Identifier
Zone goes into alarm
Alarm condition has been restored
Duress code entered at keypad
System disarmed with alarm in memory
Alarm occurs within two minutes of system arming
Panel loses/restores supervisory transmission over the
Keybus from zone expansion modules or keypads with
zone inputs
Two zones on the same partition go into alarm during any
given armed-to-armed period (incl. 24Hr zones)
Sent when the system is disarmed after an alarm, but
before the expiry of the alarm cancellation timer.
Keypad fire alarm (alarm and restore rep. codes sent
together)
Keypad auxiliary alarm (alarm and restore rep. codes sent
together)
Keypad panic alarm (alarm and restore rep. codes sent
together)
access code is entered.
Option #04: a 2-wire smoke detector wired to PGM 2 goes
into alarm/alarm is cleared.
Zone is tampered / tamper condition restored
Case/cover has a tamper alarm. Case/cover tamper
restored
Maximum number of incorrect access codes has been
entered at a keypad
System armed (user 01-39, 40 indicated)
A zone was bypassed at the time of arming
One or more zones bypassed when system armed
Closing (arming) using one of the following methods: quick
arm,
keyswitch, function key, maintenance code, DLS
software
Whenever the Auto-arm pre-alert sounds (if the Late to
Close option is enabled)
Sent when an exit error occurs and the Entry Delay
expires before the system is disarmed
System disarmed (user 01-39, 40 indicated)
Opening (disarming) using one of the following methods:
keyswitch, maintenance code, DLS software
PC1404 System battery is low/battery restored.
Appendix A: Reporting Code Formats
BA= Burglary Alarm
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
T/R
T/R
T/R
O/C
O/C
O/C
O/C
O/C
O/C
O/C
O/C
MA/R
01= Zone 1
See the tables on next
page for details
E(1)21-000 HA-00
E(4) 58-UUU
OR-UU
E(4)59-
CR-UU
UUU
E(1)43-000/
UA-00/
R(1) 43-000
UH-00
E(1)39-000 BM-00/BV-00
E(4)A6-UUU OC-UU
E(1)1A-000/
FA-00/FH-00
R(1)1A-000/
E(1)AA-000/
MA-00/MH-00
R(1)AA-000/
E(1)2A-000/
PA-00/PH-00
R(1)2A-000
E(1)4A-000/
UA-99/UH-99
R(1)4A-000
FA-99/FH-99
E(1)11-000/
R(1)11-000
E(3)83-ZZZ/
TA-ZZ/TR-ZZ
R(3)83-ZZZ/
E(1)45-000/
ES-00/EJ-00
R(1)45-000
E(4)61-000 JA-00
CL-UU
R(4)A1-UUU
E(5)7A-ZZZ UB-ZZ
E(4)56-000 CG-00
R(4)AA-000 CL-00
R(4)54-000 CI-00
E(3)74-ZZZ EA-ZZ
E(4)A1-UUU
OP-UU
E(4)AA-000 OP-00
YT-00/YR-00
E(3)A2-000/
R(3)A2-000

Hide quick links: