DSC PowerSeries PC1404 V1.1 Installation Manual page 51

Dsc power series security systems installation guide
Table of Contents

Advertisement

PC1404
This product has been tested and found in compliance with the following standards:
UL1023 Household Burglar-Alarm System Units
UL985 Household Fire Warning System Units
UL1635 Digital Alarm Communicator System Units
ULC-S545-02 Residential Fire Warning System Control Units
ORD-C1023-1974 Household Burglar-Alarm System Units
This product has also been tested and found in compliance with the ANSI/SIA CP-01-2010 Control Panel Standard – Features for False
Alarm Reduction.
This product is UL/ULC listed under the following categories:
UTOU/UTOUC Control Units and Accessories, Household System Type
NBSX/NBSXC Household Burglar Alarm System Units
AMTB Control Panels, SIA False Alarm Reduction
The product is labeled with the UL and ULC listing marks along with the SIA CP-01-2010 compliance statement (also Classified in
accordance with the SIA-CP-01-2010 Standard) as proof of compliance with the above-mentioned standards. For further information on
this product's listings, please also refer to the official listing guides published at the UL web site (www.ul.com) under the Certifications
Section.
UL/ULC Residential Fire and Burglary Installations:
For ULC Installations refer to the Standard for the Installation of Residential Fire Warning Systems, CAN/ULC-S540.
• All burglary-type zones shall be configured with SEOL, DEOL, or zone-doubling configuration.
(Refer to section [101] to [108]; bit 15 or 16 shall be ON. See also section [13] options 1, 2, and 7).
• Use at least one Smoke Detector for Fire Installations (refer to section [001]; fire zone shall be programmed as type 08 or 29 (fire
verified).
• The entry delay shall not exceed 60 seconds. (Refer to section [005].)
• The exit delay shall not exceed 120 seconds. (Refer to section [005].)
• The minimum Bell Time-out is 4 minutes. (Refer to section [005].)
Note: For ULC Residential Fire Installations the minimum Bell Time-out is 5 minutes.
• Temporal Three Fire Signal shall be enabled. (Refer to section [013]; option 8 shall be ON.)
• A code shall be required for bypassing. (Refer to section [015]; option 5 shall be ON.)
• Trouble beeps shall be enabled. (Refer to section [023]; option 7 shall be OFF.)
• AC trouble indication LED shall be enabled. [Refer to Keypad Programming (PK/RFK keypads only), section [077]; options 5 and 6
shall be ON.]
• DACT Communicator shall be enabled for Supervising Station Monitoring. (Refer to section [380]; option 1 shall be ON.)
Note: The DACT communicator for this product has no line security.
• Telephone Line Monitoring (TLM) shall be enabled (refer to section [015]; option 7 shall be ON)
Note: This product is programmed to perform 5 attempts for communication of an event to the supervising station. If unsuccessful, a
Fail To Communicate (FTC) trouble is generated.
• Test transmission cycle shall be set for monthly transmission (refer to section [377])
Note: For ULC Residential installations set for daily test transmission.
Programming
The notes in the programming sections describing the system configurations for UL/ULC listed installations shall be implemented.
Bell Location
The alarm sounding device (bell) shall be located where it can be heard by the person operating the security system during the daily
arming and disarming cycle.
Casual Users
The installer should caution the user(s) not to give system information (e.g. codes, bypass methods, etc.) to casual users (baby-sitters or
service people). Only the One-Time Use codes shall be given to casual users.
User Information
The installer should advise the users and note in the User's Manual:
Service organization name and telephone number
The programmed exit time
The programmed entry time
Test system weekly
Note: Remote arming or downloading is not applicable in UL installations.