DSC PC155O Installation Manual
Hide thumbs Also See for PC155O:
Table of Contents

Advertisement

Installation
Manual
Software Version 4.1
PC155O
DLS-1 V6.5 and later
• W A R N I N G •
This manual contains information on limitations regarding product use and function and
information on the limitations as to liability of the manufacturer.
The entire manual should be carefully read.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PC155O and is the answer not in the manual?

Questions and answers

Summary of Contents for DSC PC155O

  • Page 1: Installation Manual

    Installation Manual Software Version 4.1 PC155O DLS-1 V6.5 and later • W A R N I N G • This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Features Programming Sections Keypad Programmable ..............2 [00] Binary Programming ..............7 EEPROM Memory ................2 [01] 1st Phone Number ..............7 Static/Lightning Protection ..............2 [02] 1st Account Code ..............7 Supervision ..................2 [03] 2nd Phone Number ..............7 Operation ...................
  • Page 3: Features Keypad Programmable

    PC1500RK Keypad Features • Three keypad activated zones: Keypad Programmable Fire , Auxiliary, Panic The PC1550 is complete with a default program so that it is operational • Backlit keys with a minimum of programming. The control panel is completely •...
  • Page 4: Auxiliary Power Connection

    Wire Routing for Power and Non-Power Limited Keypad Wiring All wiring entry points are designated by the arrows. All circuits are Up to three keypads may be connected in parallel. Do not connect classified UL installation power limited except for the battery leads multiple keypads on the same keypad wire run.
  • Page 5: Auto-Bypass/Home-Away Arming

    “Bypass” light will be ON if a zone is bypassed and if Show Bypassed bypass certain zones. Lights for these zones will not come ON in response Status While Armed is programmed in section [31], zone light 4 ON. to the bypass command. See Zone Bypass Mask (section [16]). Trouble Conditions See [17] System Times for instructions on changing the Exit Delay time.
  • Page 6: User Programming Commands

    [1] Setting the Clock be programmed with the downloading computer’s telephone number, the downloading access code and the panel identification code. The System Clock is a 24 Hr. clock and times must be entered as 2-digit NOTE: [ ][4] command can be programmed to require an access numbers.
  • Page 7: Installer's Programming Command

    Installer’s Programming Command Programming Guide [ ]+[8]+[Installer’s Code] Introduction The PC1550 is completely programmed from the keypad by using The essential information which defines the operation of the control commands in the [ ][8] section. See the Programming Section of this panel is stored in a section of the EEPROM memory which is manual.
  • Page 8: Binary Data Display

    can be turned OFF at once by pressing [0]. When the correct selections have been made, press [#] to save the selections in memory and return transmission will be sent when an event takes place (i.e. alarm, restoral, to the program mode. opening / closing, trouble, etc.).
  • Page 9: Zone Restoral Reporting Codes

    If a transmission is not wanted for a particular reporting code, then enter ‘00’ or ‘FF’ to disable that reporting code. of day for the report must be entered in section [19]. [06] Zone Restoral Reporting Codes NOTE: For UL installations, either AC failure or battery trouble reporting must be enabled.
  • Page 10: 1St System Option Code

    ZONE [7] Auxiliary Delay Loop operates the same as the type [0] loop LIGHT except the entry/exit times can be independently set in section [18]. ON = Communicator disabled This loop type is useful when a loop with an entry and/or exit time •...
  • Page 11: Communication Variables

    The panel can be enabled to periodically call the downloading NO automatic arming or test transmission will take place even if those computer. The cycle time (in days) for the call is set in section [17]. functions are enabled. VALID times must be entered in this section The automatic call to the downloading computer can be used to before these features will function.
  • Page 12: Programmable Output Options

    [C] RADIONICS second period. (2300 / 1400 Hz handshake*) [05] Courtesy Pulse 3/1 extended with parity format This option provides an output which follows the entry and exit times. It can be used to turn on a courtesy light near the exit door [D] - [F] DO NOT USE for the duration of the entry / exit times.
  • Page 13: Downloading Access Code

    seconds is silenced) This 4-digit code allows the panel to confirm that it is communicating • OFF = 1 burst of bell / siren every 10 seconds during with a valid downloading computer. Enter 4 digits using the numbers Auto-Arm pre-alert 0 through 9 only.
  • Page 14: Keypad Lockout Control

    Remember that even a reset to the factory default will not change the installer’s code back to the default. NOTE: Panels returned to DSC with the installer’s lockout feature enabled and no other apparent problems will be subject to an additional service charge.
  • Page 15: For The Record

    PC1550 Version 4.1 For the Record Customer __________________________________________________________________________________________________________ Address __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ Phone ___________________________________________ Installation Date ____________________________________________ CONTACTS: #1 Name ___________________________________________ Phone _____________________________________________________ #2 Name ___________________________________________ Phone _____________________________________________________ #3 Name ___________________________________________ Phone _____________________________________________________ Installer’s Code ______________________________________ ZONES Zone Type Protected Area _____________________________ _________________________________________________________________________ _____________________________...
  • Page 16: Programming Worksheets

    PC1550 Version 4.1 Programming Work Sheets NOTE: In sections [01] to [10], do not enter data into sections that are not used. [01] 1st Phone Number Page 8 Enter [0] for the digit 0 in the phone number. Enter [ 4 ] (HEX D) for additional dial tone detection between number digits, as in local PBX systems.
  • Page 17 PC1550 Version 4.1 [11] Zone Definitions Page 10 NOTE: When defining zones, assign delay zones first to zones 1,2,3..., then assign the other zone types to the remaining zones in any order desired. Default First Digit Second Digit 0 = Slow, Audible 0 = Standard Delay Zone 1 1 = Slow, Silent...
  • Page 18 PC1550 Version 4.1 [15] Communication Variables Page 11 Default NOTE: For UL installations, the Maximum Transmissions section cannot be enabled. Also, the Delay Before Transmission must not exceed 15 seconds. Maximum transmissions per burglary zone Enter digits from “01” to “99” for number of transmissions per zone during the period as defined in Section [12], 1st System Option Code, Zone Light 2.
  • Page 19 PC1550 Version 4.1 [23] Communication Formats Page 12 It is necessary to program the format for both numbers, even if the second telephone number is not used. Default Default 1st Telephone Number 2nd Telephone Number Enter one HEX digit from [0] to [F] for each phone number from the following list: SILENT KNIGHT / ADEMCO SLOW 10 BPS (1400 Hz handshake) 3/1, 4/1 and 4/2 non-extended formats...
  • Page 20 Number of Invalid Codes before lockout Lockout Duration (minutes) [90] Installer’s Lockout Enable Page 14 [91] Installer’s Lockout Disable Page 14 WARNING! Panels returned to DSC with the Installer’s Lockout enabled and no other apparent problems will be subject to an additional service charge!
  • Page 21: Pc1550 Control Panel Wiring Diagram

    PC1550 Control Panel Wiring Diagram Incorrect connections may result in PTC failure or improper operation. Inspect wiring and ensure connections are correct before applying power. Do not route any wiring over circuit boards. Maintain at least 1” (25.4mm) distance.
  • Page 22: Ul Listed Residential Installations

    UL Listed Residential Installations Residential Installations Protection of the Control Unit • The entry delay must not exceed 45 seconds The local control and the local power supply must be protected by one of • The exit delay must not exceed 60 seconds. the following ways: •...
  • Page 23: Limited Warranty

    Installer’s Lockout could be heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam vents, lighting and so on. Any products returned to DSC which have the Installer’s Lockout option enabled and Warning Devices exhibit no other problems will be subject to a service charge.
  • Page 24 1-800-387-3630 © 2001 Digital Security Controls Ltd. Toronto, Canada • www.dsc.com Printed in Canada 29003080 R003...