that have been automatically bypassed with the [*][9] command. Delay Stay/Away and Interior Delay Zones will still have Entry Delay
on a [*][9] armed panel.
[
][0] – Quick Arm
*
When disarmed, press [*][0] to activate Quick Arm. Quick Arm may be used as a convenience for regular users or when the system is
to be armed by individuals who are not authorized to disarm the system. This panel will log either "Armed in Stay Mode" or "Armed in
Away Mode" for this closing type.
[
][0] – Quick Exit
*
When armed, press [*][0] to activate Quick Exit. Quick Exit allows the user 2 minutes to exit the premises through any delay zone with-
out altering the status of the system if the Quick Exit feature is enabled. After [*][0] is entered, one and only one delay zone may be
tripped. If the delay zone is left unrestored at the end of the 2 minutes, it will begin its entry delay sequence. Any additional activity on
any other active zone will cause that zone to begin its alarm or delay sequence. Quick Exit is not designed to extend the standard Exit
Delay.