8.1 Precautions for Data Setting

The default display mode limits the screens (parameters) that can be displayed on the monitor. To enable the display of all parameters, specify "00" (full display) for the function code display
restriction (b037).
To enable the parameters to be changed while the inverter is operating, specify "10" for the software lock mode selection (b031).

8.2 Monitoring Mode

With the default settings, the monitor always displays the data output according to the output frequency monitoring (d001) after power-on. To change the initial display content, change the setting
of the initial-screen selection (b038) as required.
Code
Function name
d001
Output frequency monitoring
d002
Output current monitoring
d003
Rotation direction minitoring
d004
Process variable (PV), PID feedback
monitoring
d005
Intelligent input terminal status
d006
Intelligent output terminal status
d007
Scaled output frequency monitoring
d008
Actual-frequency monitoring
d009
Torque command monitoring
d010
Torque bias monitoring
d012
Torque monitoring
d013
Output voltage monitoring
d014
Power monitoring
d015
Cumulative power monitoring
d016
Cumulative operation RUN time
monitoring
d017
Cumulative power-on time monitoring
d018
Heat sink temperature monitoring
d019
Motor temperature monitoring
d022
Life-check monitoring
d023
Program counter
d024
Program number monitoring
Monitored data or setting
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 999.9, 1000 to 9999 (A)
F (forward rotation), o (stopped), r (reverse rotation)
0.00 to 99.99, 100.0 to 999.9, 1000. to 9999.
1000 to 9999 (10000 to 99990), ⎡100 to ⎡999 (100000 to 999000)
FW
6
4
8
7
5
3 2
1
AL 15 14 13 12
11
0.00 to 99.99, 100.0 to 999.9, 1000. to 9999., 1000 to 3996 (10000 to 39960)
-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz)
-150. to +150. (%)
-150. to +150. (%)
-150. to +150. (%)
0.0 to 600.0 (V)
0.0 to 999.9 (kW)
0.0 to 999.9, 1000. to 9999.
1000 to 9999 (10000 to 99990), ⎡100 to ⎡999 (100000 to 999000)
0. to 9999., 1000 to 9999 (10000 to 99990), ⎡100 to ⎡999 (100000 to 999000) (hr)
0. to 9999., 1000 to 9999 (10000 to 99990), ⎡100 to ⎡999 (100000 to 999000) (hr)
-020. to 200.0 (°C)
-020. to 200.0 (°C)
2
1
0 to 1024
0000 to 9999
8 - 1
Chapter 8 List of Data Settings
(Example)
Terminals FW, 7, 2, and 1: ON
Terminals 8, 6, 5, 4, and 3: OFF
(Example)
Terminals 12 and 11: ON
Terminals AL, 15, 14, and 13: OFF
1: Capacitor on main circuit board
2: Cooling-fan speed drop
ON
OFF
Setting during
Change during
operation
operation
Default
(allowed or not)
(allowed or not)
Page
4-1
4-1
4-1
4-1
4-2
4-2
4-2
4-3
4-3
4-3
4-3
4-3
4-3
4-4
4-4
4-4
4-4
4-4
4-5
4-5
4-5