The torque biasing function allows you to make the inverter bias the
torque command generated during the operation in speed control mode.
You can effectively use this function for inverter applications to a lift or
other elevating machines.
Item
Torque biasing mode
selection
Torque bias setting
Torque biasing polarity
selection (*2)
*1 When the torque bias is set as a signal input via the O2 terminal, the inverter recognizes the signal
voltage -10 to +10 (V) as the bias value -150 to +150 (%).
*2 1) When "00" (depending on the sign of the bias value) is specified:
Regardless of the direction of motor rotation, torque in the forward direction increases when the
torque bias signal indicates a positive (+) value. Torque in the reverse direction increases when
the torque bias signal indicates a negative (-) value.
2) When "01" (depending on the motor rotation direction) is specified:
The sign of the bias value indicated by the torque bias signal and the direction of the torque
biasing change according to the rotation direction specified by the operation command.
With a forward operation command: the torque is generated in the same direction as that specified
by the sign of the torque bias value.
With a reverse operation command: the torque is generated in the opposite direction to that
specified by the sign of the torque bias value.

4.3.5 Torque control function

The torque control function is effective in the V2 control mode.
You can use the inverter not only under the speed control or
pulse train position control but also with this torque control
function. You can use this function effectively for inverter
applications to, for example, a winding machine.
To operate the inverter to drive the motor under torque control,
assign function "52" (ATR) to an intelligent input terminal. The
torque command input is enabled when the ATR terminal is on.
You can select one of four torque command input methods
(digital operator and three analog input terminals) by the torque
command input selection (P034).
Item
Torque command input
selection
Torque command setting
Polarity selection at the torque
command input via the O2
terminal
Speed limit for
torque-controlled operation
(forward rotation)
Speed limit for
torque-controlled operation
(reverse rotation)
Torque biasing mode selection
Torque bias setting
Torque biasing polarity
selection
Terminal function
Function code
Data or range of data
P036
P037
-150 to +150 (%)
P038
Function code
Data or range of data
P033
P034
P035
0.00 to 99.99 or 100.0 to
P039
0.00 to 99.99 or 100.0 to
P040
P036
P037
-150 to +150 (%)
P038
C001 to C008
00
None
01
Bias setting from the digital operator
02
Bias setting via the O2 terminal (*1)
Valid when "P036" = "01"
00
Depending on the sign of bias value
01
Depending on the motor rotation direction
P033: Torque command input selection
P034: Torque command setting
P035: Polarity selection at the torque
command input via the O2 terminal
P039: Speed limit for torque-controlled
operation (forward rotation)
P040: Speed limit for torque-controlled
operation (reverse rotation)
d009/d010/d012: Torque command monitoring
P036: Torque biasing mode selection
P037: Torque bias setting
P038: Torque biasing polarity selection
d010: Torque bias monitoring
C001 to C008: Terminal [1] to [8] functions
00
Input from the O terminal
01
Input from the OI terminal
02
Input from the O2 terminal
03
Input from the digital operator
Torque setting for the input from the digital
0 to 150 (%)
operator (P033 = 03)
00
Depending on the sign of torque value
01
Depending on the motor rotation direction
400.0 (Hz)
400.0 (Hz)
00
None
01
Bias setting from the digital operator
02
Bias setting via the O2 terminal
Valid when "P036" = "01"
00
Depending on the sign of bias value
01
Depending on the motor rotation direction
52
ATR: Permission for torque command input
4 - 98
Related code
P036: Torque biasing mode selection
P037: Torque bias setting
P038: Torque biasing polarity selection
d010: Torque bias monitoring
Description
Related code
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents