Chapter 5 Error Codes
Display on
Name
operator
Gate array com-
munication error
Phase loss input
protection
Main circuit error
IGBT error
Thermistor error
Braking error
Emergency stop
Low-speed over-
load protection
Modbus com-
munication error
Option 1 error
Option 2 error
Waiting in under-
voltage status
Communication
error
Waiting for retry
Power-off
Restricted
operation
command
Initialization
(Rotation display)
Empty trip history
Display on
digital
remote
operator
GA.COM
PH.fail
Main.Cir
IGBT
TH
BRAKE
EMR
OL-LowSP
NET.ERR
OP1-0
OP1-9
OP2-0
OP2-9
UV.WAIT
R-ERROR COMM<1>
R-ERROR COMM<2>
RESTART
ADJUST
POWER OFF
RUN.CMD DISABLE
055HFF~150HFF
Use the control circuit terminal for resetting, press the
STOP/RESET key of the digital operator or turn on/off the
power of inverter
Turn on/off the power of inverter
Turn on/off the power of
inverter
Use the control circuit terminal for resetting, press the
STOP/RESET key of the digital operator or turn on/off the
power of inverter
Self resetting when input voltage satisfy the condition
Self resetting when operator communication is normal and turn
on/off the power
Display will be normal after standby mode ended
Display will be normal after run command is normal
Display will be normal after initialization ended
5 - 12
185HFF~550HFF
Use the control circuit terminal
for resetting, press the
STOP/RESET key of the digital
operator or turn on/off the power
of inverter
-
-