125Fh
PID Function Enable
1260h
PID proportional gain
1261h
PID integral time constant
1262h
PID derivative gain
1263h
PV scale conversion
1264h
PV source setting
1265h
Reverse PID
1266h
PID output limiter
1267h
PID feed forward selection
1268h
(Reserved)
1269h
AVR function select
126Ah
AVR voltage select
126Bh
(Reserved)
126Ch
(Reserved)
126Dh
Operation mode selection
126Eh
Energy saving mode tuning
126Fh to
(Reserved)
1273h
1274h
Acceleration (2) time
setting
1275h
1276h
Deceleration (2) time
setting
1277h
Select method to switch to
1278h
Acc2/Dec2 profile
1279h
Acc1 to Acc2 frequency
transition point
127Ah
127Bh
Dec1 to Dec2 frequency
transition point
127Ch
Acceleration curve
127Dh
selection
127Eh
Deceleration curve setting
127Fh
(Reserved)
1280h
(Reserved)
1281h
[OI]-[L] input active range
start frequency
1282h
1283h
[OI]-[L] input active range
end frequency
1284h
[OI]-[L] input active range
1285h
start current
[OI]-[L] input active range
1286h
end current
[OI]-[L] input start
1287h
frequency enable
1288h to
(Reserved)
128Ch
128Dh
[O2]-[L] input active range
start frequency
128Eh
128Fh
[O2]-[L] input active range
end frequency
1290h
[O2]-[L] input active range
1291h
start voltage
[O2]-[L] input active range
1292h
end voltage
1293h to
(Reserved)
12A4h
Acceleration curve
12A5h
constants setting
Deceleration curve
12A6h
constants setting
12A7h to
(Reserved)
12AEh
Operation-target frequency
12AFh
selection 1
Function code
R/W
0 (disabling), 1 (enabling), 2 (enabling inverted-data
A071
R/W
output)
A072
R/W 2 to 50
A073
R/W 0 to 36000
A074
R/W 0 to 10000
A075
R/W 1 to 9999
0 (input via OI), 1 (input via O), 2 (external
A076
R/W
communication), 3 (pulse train frequency input), 10
(operation result output)
A077
R/W 00 (disabling), 01 (enabling)
A078
R/W 0 to 1000
A079
R/W 0 (disabled), 1(O input), 2 (OI input), 3 (O2 input)
-
R/W Inaccessible
A081
R/W 0 (always on), 1 (always off), 2 (off during deceleration)
200 V class: 0 (200)/1 (215)/2 (220)/3 (230)/4 (240)
A082
R/W
400 V class: 5 (380)/6 (400)/7 (415)/8 (440)/9 (460)/ 10
(480)
-
R/W Inaccessible
-
R/W Inaccessible
0 (normal operation), 1 (energy-saving operation), 2
A085
R/W
(fuzzy operation)
A086
R/W 0 to 1000
-
-
Inaccessible
A092 (high)
R/W
1 to 360000
A092 (low)
R/W
A093 (high)
R/W
1 to 360000
A093 (low)
R/W
A094
R/W 0 (switching by 2CH terminal), 1 (switching by setting)
A095 (high)
R/W
0 to 40000
A095 (low)
R/W
A096 (high)
R/W
0 to 40000
A096 (low)
R/W
0 (linear), 1 (S curve), 2 (U curve), 3 (inverted-U
A097
R/W
curve), 4 (EL-S curve)
0 (linear), 1 (S curve), 2 (U curve), 3 (inverted-U
A098
R/W
curve), 4 (EL-S curve)
-
-
Inaccessible
-
-
Inaccessible
A101 (high)
R/W
0 to 40000
A101 (low)
R/W
A102 (high)
R/W
0 to 40000
A102 (low)
R/W
A103
R/W 0 to "[OI]-[L] input active range end current"
A104
R/W "[OI]-[L] input active range start current" to 100
A105
R/W 0 (external start frequency), 1 (0 Hz)
-
-
Inaccessible
A111 (high)
R/W
-40000 to 40000
A111 (low)
R/W
A112 (high)
R/W
-40000 to 40000
A112 (low)
R/W
A113
R/W -100 to "[O2]-[L] input active range end voltage"
A114
R/W "[O2]-[L] input active range start voltage" to 100
-
-
Inaccessible
A131
R/W 1 (smallest swelling) to 10 (largest swelling)
A132
R/W 1 (smallest swelling) to 10 (largest swelling)
-
-
Inaccessible
0 (digital operator), 1 (keypad potentiometer), 2 (input
A141
R/W
via O), 3 (input via OI), 4 (external communication), 5
(option 1), 6 (option 2), 7 (pulse train frequency input)
4 - 147
Chapter 4 Explanation of Functions
Monitoring and setting items Data resolution
Register
No.
-
0.1
0.1 [sec.]
0.01 [sec.]
0.01
-
-
0.1 [sec.]
-
-
-
-
-
-
-
0.1 [%]
-
0.01 [sec.]
0.01 [sec.]
-
0.01 [Hz]
0.01 [Hz]
-
-
-
-
0.01 [Hz]
0.01 [Hz]
1 [%]
1 [%]
-
-
0.01 [Hz]
0.01 [Hz]
1 [%]
1 [%]
-
-
-
-
-