Hitachi SJ700B Series Instruction Manual page 260

Sj700b series inverter
Hide thumbs Also See for SJ700B Series:
Table of Contents

Advertisement

Code
Function name
b034
Run/power-on warning time
b035
Rotational direction restriction
b036
Reduced voltage start selection
b037
Function code display restriction
b038
Initial-screen selection
Automatic user-parameter setting
b039
function enable
b040
Torque limit selection
Torque limit (1) (forward-driving in
b041
4-quadrant mode)
Torque limit (2)
b042
(reverse-regenerating in
4-quadrant mode)
Torque limit (3) (reverse-driving in
b043
4-quadrant mode)
Torque limit (4)
b044
(forward-regenerating in
4-quadrant mode)
b045
Torque limit LADSTOP enable
b046
Reverse Run protection enable
Controller deceleration and stop on
b050
power loss
DC bus voltage trigger level during
b051
power loss
Over-voltage threshold during
b052
power loss
Deceleration time setting during
b053
power loss
Initial output frequency decrease
b054
during power loss
Proportional gain setting for
b055
nonstop operation at power loss
Integral time setting for nonstop
b056
operation at power loss
Maximum-limit level of window
b060
comparators O
Minimum-limit level of window
b061
comparators O
Hysteresis width of window
b062
comparators O
Maximum-limit level of window
b063
comparators OI
Minimum-limit level of window
b064
comparators OI
Hysteresis width of window
b065
comparators OI
Maximum-limit level of window
b066
comparators OI
Minimum-limit level of window
b067
comparators O/OI/O2
Hysteresis width of window
b068
comparators O/OI/O2
b070
Operation level at O disconnection
b071
Operation level at OI disconnection
Operation level at O2
b072
disconnection
Monitored data or setting
0. to 9999. (0 to 99990), 1000 to 6553 (100000 to 655300) (hr)
00 (enabling both forward and reverse rotations), 01 (enabling only
forward rotation), 02 (enabling only reverse rotation)
0 (minimum reduced voltage start time) to 255 (maximum reduced
voltage start time)
00 (full display), 01 (function-specific display), 02 (user setting), 03
(data comparison display), 04 (basic display)
00 (screen displayed when the STR key was pressed last), 01 (d001),
02 (d002), 03 (d003), 04 (d007), 05 (F001)
00 (disabling), 01 (enabling)
00 (quadrant-specific setting), 01 (switching by terminal), 02 (analog
input), 03 (option 1), 04 (option 2)
0. to 150. (%), no (disabling torque limitation)
0. to 150. (%), no (disabling torque limitation)
0. to 150. (%), no (disabling torque limitation)
0. to 150. (%), no (disabling torque limitation)
00 (disabling), 01 (enabling)
00 (disabling), 01 (enabling)
00 (disabling), 01 (nonstop deceleration to stop), 02 (DC voltage
constant control, with resume), 03 ( without resume)
0.0 to 999.9, 1000. (V)
0.0 to 999.9, 1000. (V)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.00 to 10.00 (Hz)
0.00 to 2.55
0.000 to 9.999 /10.00 to 65.53 (s)
0. to 100. (lower limit : b061 + b062 *2) (%)
0. to 100. (lower limit : b060 - b062 * 2) (%)
0. to 10. (lower limit : b061 - b062 / 2) (%)
0. to 100. (lower limit : b064 + b066 *2) (%)
0. to 100. (lower limit : b063 - b066 *2) (%)
0. to 10. (lower limit : b063 - b064 / 2) (%)
-100. to 100. (lower limit : b067 + b068* 2) (%)
-100. to 100. (lower limit : b066 - b068 * 2) (%)
0. to 10. (lower limit : b066 - b067 / 2) (%)
0. to 100. (%) or "no" (ignore)
0. to 100. (%) or "no" (ignore)
-100. to 100. (%) or "no" (ignore)
8 - 7
Chapter 8 List of Data Settings
Setting
Change
during
operation
operation
Default
(allowed or
(allowed or
not)
0.
00
6
04
01
00
00
120.
120.
120.
120.
00
00
00
220.0/44
0.0
360.0/72
0.0
1.00
0.00
0.20
0.100
100
0
0
100
0
0
100
0
0
no
no
no
during
Page
not)
4-64
4-7
4-42
4-76
4-78
4-79
4-92
4-94
4-93
4-83
4-71

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents