Chapter 4 List of Data Settings

4.1 Precautions for Data Setting

The default display mode limits the screens (parameters) that can be displayed on the monitor. To enable
the display of all parameters, specify "00" (full display) for the function code display restriction (b037).
To enable the parameters to be changed while the inverter is operating, specify "10" for the software lock
mode selection (b031).

4.2 Monitoring Mode

With the default settings, the monitor always displays the data output according to the output frequency
monitoring (d001) after power-on. To change the initial display content, change the setting of the
initial-screen selection (b038) as required.
Code
Function name
d001 Output frequency monitoring
d002 Output current monitoring
d003 Rotation direction minitoring
Process variable (PV),
d004
PID feedback monitoring
d005 Intelligent input terminal status
d006 Intelligent output terminal status
Scaled output frequency
d007
monitoring
d012 Torque monitoring
d013 Output voltage monitoring
d014 Power monitoring
d015 Cumulative power monitoring
Cumulative operation RUN time
d016
monitoring
Cumulative power-on time
d017
monitoring
d018 Heat sink temperature monitoring -020. to 200.0 (°C)
d019 Motor temperature monitoring
d022 Life-check monitoring
d023 Program counter
d024 Program number monitoring
Monitored data or setting
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 999.9, 1000 to 9999 (A)
F (forward rotation), o (stopped), r (reverse rotation)
0.00 to 99.99, 100.0 to 999.9, 1000. to 9999.
1000 to 9999 (10000 to 99990), ⎡100 to ⎡999 (100000 to 999000)
FW
6
4
8
7
5
3 2
1
AL 15 14 13 12
11
0.00 to 99.99, 100.0 to 999.9, 1000. to 9999.,
1000 to 3996 (10000 to 39960)
-200. to +200. (%)
0.0 to 600.0 (V)
0.0 to 999.9 (kW)
0.0 to 999.9, 1000. to 9999.1000 to 9999 (10000 to 99990),
⎡100 to ⎡999 (100000 to 999000)
0. to 9999., 1000 to 9999 (10000 to 99990),
⎡100 to ⎡999 (100000 to 999000) (hr)
0. to 9999., 1000 to 9999 (10000 to 99990),
⎡100 to ⎡999 (100000 to 999000) (hr)
-020. to 200.0 (°C)
2
1
0 to 1024
0000 to 9999
4 - 2
(Example)
Terminals FW, 7, 2, and 1: ON
Terminals 8, 6, 5, 4, and 3: OFF
(Example)
Terminals 12 and 11: ON
Terminals AL, 15, 14, and 13: OFF
ON
1: Capacitor on main circuit board
OFF
2: Cooling-fan speed drop
Setting
Change
during
during
Default
operation
operation
(allowed
(allowed
or not)
or not)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents