Specifications; Installation - Kelvinator KWH16CMF User Manual

Window wall (manual) room air conditioner

Advertisement

Spec cations
Unit dimensions:
Model (kW)
< 1.6kW
Suggest minimum wire size (AWG:American Wire Gage):
Appliance Amps
10

Installation

Select the best location
1
To avoid vibration and noise, make sure the unit is
installed securely an
rmly.
2
Install the unit where the sunlight does not shine directly
on the unit.
If the unit receives direct sunlight, build an awning to
shade the cabinet.
3
There should be no obstacle, such as a fence or wall,
within 50cm from the back of the cabinet because it will
prevent heat radiation of the condensor.
Restriction of outside air will greatly reduce the cooling
and heating e ciency of the air conditioner.
4
Install the unit with rear angled down so as not to leak
condensed water into the room (about 3°~4° angle with
level).
5
Install the unit with its bottom portion 75~150cm above
th
oor level.
6
T
h
e
p
o
w
r e
c
o
d r
m
u
t s
b
e
circuit. The yellow/green wire must be grounded.
7
Based on calculations in compliance with AS60335.2.40
there is no minimum saf
the air conditioners described in this manual.
8
After installation the power plug should be easily
accessible.
9
Ensure clearance around the air conditioner meets the following:
Minimum 150mm above the air conditioner
Minimum 150mm on left and right side of the air conditioner
Minimum 1,000mm in front of the air conditioner
Minimum 500mm to rear of the air conditioner
TOP VIEW
Fence or
likewise
Over 500mm
Over
150mm
8 spec cations/installation Kelvinator Air Conditioning
Body dimension (mm)
(WxHxD)
450x350x580
AWG Wire Size
18
c
o
n
n
e
c
e t
d
o t
a
n
n i
d
e
p
e
n
d
e
t n
oor area for the installation of
FRONT VIEW
Over
150mm
less than 220mm
more than
60mm
wall thickness is less than 220mm
more
than
150mm
brick cut away
if the wall thickness is more than 220mm
45° brick cut away to install louvres properly.
Ceiling
Over 150mm
Over
1000mm
make rear of the airconditioner (outside)
lower than the front of the airconditioner
(inside) to allow water to drain
less than 220mm
more
than
150mm
more than 500mm
SIDE VIEW
Over 150mm
Over
500mm
Less than 220mm