APPROVALS
The HTZ-2000 air duct kit is approved to use on Heatilator
Maxus gas fireplaces and on Aladdin Hearth Products
Quadra-Fire QFP30 gas fireplace.
INTRODUCTION
The HTZ-2000 accessory kit conveys warm air from the
fireplace through air duct(s) to remote locations in the same
room or other rooms of the building. See Figure 1. One or two
HTZ-2000 kits can be installed on the fireplace.
PRELIMINARY PREPARATION
1. Contents of kit:
* 20-ft. length of 6" round duct
* Fan housing assembly
* Junction box
* Variable Wall Rheostat
* Air register
* Register adapter frame - Thick
* Fireplace duct collar
* Duct adapter - (round to oval)
* Hardware
If any parts are missing or
damaged, contact your Dealer
before starting installation. DO
NOT install a damaged kit.
FIG. 1
Wall Register
Page 44
QFP 30 Direct Vent Gas Fireplace
AIR DUCT KIT INSTALLATION INSTRUCTIONS
PART #HTZ-2000
Floor Register
2. This kit is tested and safe when installed in accordance
with this installation manual. It is your responsibility to read
all instructions before starting installation and to follow these
instructions carefully during installation.
3. Installation of this kit MUST be performed by a qualified
service technician.
4. The HTZ-2000 kit is carefully engineered and must be
installed only as specified. If you modify it or any of its
components you will void the warranty, and you may possibly
cause a fire hazard. Installation must be done according to
applicable local, state, provincial, and/or national codes.
5. CAUTION: All wiring should be done by a qualified electrician
and shall be in compliance with local codes and with the
National Electric Code ANSI/NFPA No. 70-current (In the
United States), or with the current CSC22.1 Canadian Electric
Code (in Canada).
6. Plan the location of the fireplace and the warm air duct
run(s).
MAXIMUM Duct Run = 20-ft. (6.1m) for useful heat
output.
MINIMUM Duct Run = NA - for runs out from the
fireplace to adjacent room OR down to the room below.
Ceiling Register
2 DUCT KITS
03/21/01 #250-6120