Appliance Set-Up

A. Outside Air Kit Installation
A source of air (oxygen) is necessary in order for
combustion to take place. Whatever combustion air is
consumed by the fire must be replaced. Air is replaced via
air leakage around windows and under doors. In homes
that have tightly sealed doors and windows, an outside air
source is needed. An optional Outside Air Kit is available.
Included in OAK-ACC: Termination cap, (2) wire ties, flex
adapter, and fasteners
Included in SRV7033-041: Cover plate and sealing rope
(see Floor Installation Alternative below, Figure 16.2)
Items Needed for Installation (not supplied)
-
4 inch flex aluminum pipe, or if using alternate
material, then it shall be made from durable,
non-combustible, heat resistant material up to
350°F. Cut the pipe to the required length for
your installation.
-
Phillips head screw driver
-
Silicone sealant
-
Drills and saws necessary for cutting holes through
the wall or flooring in your home.
1. Remove all materials from packing box.
2. Using a #2 Phillips screw driver attach the flex adapter
to the appliance using 4 screws (Figure 16.1).
3. For floor installations, remove circular" knock-out" in the
base of the pedestal.
4. Floor & Rear Installation:
Cut a 4 inch (102mm) hole in outside wall or floor to
accommodate outside air piping. Use 4 inch (102mm)
aluminum metal flex or rigid piping to directly connect
outside air to appliance intake. Use the supplied
termination cap with a rodent screen. Seal between
the wall (or floor) and the pipe with silicone to prevent
moisture penetration.
5. Floor Installation Alternative:
In some instances you may not be able to install the
flex pipe as show in Figure 16.1. If that is the case, you
will need to order SRV7033-041 which includes a cover
plate and sealing rope as shown in Figure 16.2. The
goal is to seal the pedestal so no room air can leak into
the pedestal or for cold air infiltration.
For Floor Installa-
tions Remove
Circular "Knock-Out"
in Base of Pedestal.
Flex Line
Figure16.1 - Floor & Rear Installation
16
Flex Adapter
Wire Tie
Termination
Cap
Wire Tie
Fire Risk. Asphyxiation Risk.
Do not draw outside combustion air from:
Wall, floor or ceiling cavity
Enclosed space such as an attic
or garage
Close proximity to exhaust vents
or chimneys
Fumes or odor may result
Asphyxiation Risk.
Outside air inlet must be located to prevent
blockage from:
Leaves
Snow or ice
Other debris
Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate
sensitive individuals.
Asphyxiation Risk.
Length of outside air supply duct shall NOT
exceed the length of the vertical height of the
exhaust flue.
Fire will not burn properly
Smoke spillage occurs when door is
opened due to air starvation.
Rope to Seal
Pedestal
Figure 16.2
7033-350E
WARNING
WARNING
WARNING
September 9, 2019
Cover
Plate