Manufacturer's conversion kit supplied with the fireplace is required for this procedure.
NOTE: If converting this unit to propane, so do at this point of installation.
THE INSTALLATION OF THIS CONVERSION KIT MUST ONLY BE UNDER-
TAKEN BY A QUALIFIED AND CERTIFIED GAS APPLIANCE INSTALLER.
This conversion kit shall be installed by a qualified service agency in accordance
with the manufacturer's instructions and all applicable codes and requirements of the
authority having jurisdiction. If the information in these instructions is not followed
exactly, a fire, explosion or production of carbon monoxide may result causing property
damage, personal injury or loss of life. The qualified service agency is responsible
for the proper installatin of this kit. The installation is not proper and complete until
the operation of the converted appliance is checked as specified in the manufacturer's
CAUTION! DISCONNECT ANY ELECTRICAL CORDS AND
TURN OFF GAS SUPPLY TO UNIT BEFORE PROCEED-
ING.
Valve Regulator Tower
1.
Turn control knob to the OFF position and shut off the
gas supply to the valve.
2.
Using a Torx TH20, or slotted screwdriver, remove the
three pressure regulator mounting screws (A), pressure
regulator tower (B), and diaphragm (C). (You may wish
to retain these items for converting back to original gas
if necessary.)
3.
Insure that the rubber gasket (D) is properly positioned
and install the new HI/LO pressure regulator assembly to
the valve using the new screws (E) supplied with the kit.
Tighten screws securely. (Reference torque = 25in/lb)
4.
Install the enclosed identification label (F) to the valve
body where it can be seen.
Continued on next page.
03/21/01 #250-6120
QFP 30 Direct Vent Gas Fireplace

LP CONVERSION INSTRUCTIONS

WARNING!
WARNING !
instructions supplied with the kit.