Appliance Set-Up

A. Outside Air Kit Installation
A source of air (oxygen) is necessary in order for combustion
to take place. Whatever combustion air is consumed by the
fi re must be replaced. Air is replaced via air leakage around
windows and under doors. In homes that have tightly sealed
doors and windows, an outside air source is needed. An optional
Outside Air Kit is available.
Items Needed for Installation (not supplied)
• 4 inch fl ex aluminum pipe, or if using alternate material,
then it shall be made from durable, non-combustible, heat
resistant material up to 350
length for your installation.
• Phillips head screw driver
• 5/32 Allen Wrench
• Silicone sealant
Option One - Outside Air Installation Instructions
1. Swing grille down to expose the two screws. Figure
18.1.
2. Remove the two screws and pull the access assembly
away from the appliance.
3. Assemble the outside air cover plate A supplied in com-
ponent pack.
4. Re-install the access assembly.
5. Remove the outside air cover plate B on outer can and dis-
card. Figure 18.2.
6. Install optional fl ex adapter to outer can with the same
screws. Do not use plastic wire ties that come with the kit
as they will melt. NOTE: You may need to install the fl ex
pipe into the fi rebox fi rst depending on installation. Attach
fl ex to adapter with at least 2 screws.
7. Ensure existing access hole in fi replace is suffi cient to feed
the 4 inch fl ex.
8. After sliding can into fi replace, feed fl ex into cut opening to
obtain outside combustion air.
9. Level outer can and install appliance. See page 19.
Option Two - Outside Air Installation Instructions
1. Follow steps 1-5 in Option One above
2. Ensure existing access hole in fi replace will not be covered
by the outer can. Existing outside air intake hole may be
under at the rear or side of outer can. Outside air may also
enter down existing chimney chase in some situations.
Asphyxiation Risk.
Outside air inlet must be located to prevent
blockage from:
• Leaves, snow, ice or other debris Block may cause
combustion air starvation
• Smoke spillage may set off alarms or irritate sensitive
individuals.
18
o
F. Cut the pipe to the required
WARNING
3. Repeat step 9 under Option One with one exception. After
installing the appliance in the outer can, seal the fi replace
opening and trim package with insulation to prevent air leak-
age into the room.
Fire Risk.
Asphyxiation Risk.
Do not draw outside combustion air from:
Wall, fl oor or ceiling cavity
Enclosed space such as an attic or garage
Close proximity to exhaust vents or
chimneys
Fumes or odor may result
Asphyxiation Risk.
Length of outside air supply duct shall NOT exceed
the length of the vertical height of the exhaust fl ue.
• Fire will not burn properly
• Smoke spillage occurs when door is opened due
to air starvation.
Grille hinges
downward
Remove Screws &
Pull Access Assembly
away from Insert
Figure 18.1
Figure 18.2
7075-209E
WARNING
WARNING
Remove Outside Cover
Plate A (Discard)
Outside Air Cover
Plate B (Discard)
Termination
Flex Adapter
August 3, 2015
Cap