Safety Notices; Main Burner Operation; Gas Buildup Prevention Feature - Quadra-Fire QFP 30 Operation & Maintenance Manual

Direct vent gas fireplace
Table of Contents

Advertisement

Many of the components within this fireplace are designed
specifically for safety purposes. It is therefore imperative
that only certified gas service technicians install and
service this fireplace.

Main Burner Operation:

A millivolt system controls the operation of this
fireplace. The thermopile and thermocouple generate
electricity when heated by the pilot flame. This electricity is
used to operate the gas valve. Without enough electricity, the
gas valve will not turn on. That is why when starting the pilot
the gas control knob has to be pressed in long enough for the
thermocouple to heat up and generate enough electricity. The
thermopile provides power for the ON/OFF switch, remote
control, or thermostat. Because the thermopile generates
the electricity needed to turn the fireplace on and off, this
fireplace can be operated when the power is out (although
the blower will not run).

Gas Buildup Prevention Feature:

This appliance's utilization of a high-technology gas
valve in conjunction with a pilot flame ensures that no gas
builds up inside the firebox.
The thermocouple (next to the pilot) senses when the
pilot flame is lit. If the pilot flames goes out, this thermocouple
no longer generates electricity, causing the gas valve to
automatically shut off all gas to the heater, preventing the
pilot from spilling gas into the firebox.
Strict adherence to the instructions in this manual must
be followed. Improper installation will void the warranty
and safety listing.
This appliance is manufactured to operate on natural
gas (NG). It is field convertible to propane (LP) with the
manufacturers' conversion kit included with fireplace.
Burning incorrect fuel voids the warranty and safety listing
and may cause an extreme safety hazard.
Contact local building officials to obtain a permit and
information on installation restrictions or requirements in
your locale. It is also important to notify your homeowner's
insurance company of the installation of this appliance
as well.
Do not store or use gasoline or other flammable liquids
in the vicinity of the appliance.
If the flame becomes sooty, dark orange in color, or
extremely tall, DO NOT operate the appliance. Contact
your dealer and arrange for servicing immediately.
DO NOT operate the appliance if it is not operating
properly in any manner. Contact your dealer for
assistance.
DO NOT operate the appliance if any portion was
submerged in water or if any corrosion occurs.
Do not place clothing or other flammable items on or near
the appliance at any time. Due to thermostatic control,
the possibility exists for the appliance to turn on, igniting
any items on or near it.
Open viewing glass for servicing only.
Operate the appliance in accordance with the instructions
contained in this manual.
If the main burners do not start correctly, turn the gas
off at the gas control valve and contact your dealer
for service.
Page 8
QFP 30 Direct Vent Gas Fireplace

SAFETY NOTICES

This unit is not for use with solid fuel. DO NOT place
anything inside the firebox other than the brickset, logset,
lava rock and mineral wool included with the fireplace.
If the logs become damaged refer to Parts and Accessories
page of this manual for replacement.
Face surfaces can become extremely hot during opera-
tion. Instruct your family and guests of this danger and
supervise young children when they are in the same
room as the heater.
Instruct everyone in the house how to shut the gas off
to the appliance and also at the main gas shut-off valve.
The gas main shut-off valve is usually next to the gas
meter or propane tank and requires a wrench to shut
off. The manual shut-off valve will be installed by your
installer near the fireplace.
Use the built-in piezo igniter to light the appliance. Do not
use matches or any other external device.
Allow the appliance to cool before carrying out any
maintenance or cleaning.
The pilot flame must contact the thermopile and thermo-
couple. If it does not, turn the gas control valve to "OFF"
and call your Dealer.
DO NOT away throw this manual. Important operating
and maintenance instructions are included.
DO NOT remove, replace, modify or substitute any
part of the appliance.
Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies.
Children and adults should be alerted to the hazards
of high surface temperature and should stay away to
avoid burns or lothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other flammable material should not be
placed on or near the appliance.
Any safety screen or guard removed for servicing
an appliance must be replaced prior to operating
the appliance.
Installation and repair should be done by a qualified
service person. The appliance should be inspected
before use and at least annually by a professional
service person. More frequent cleaning may be
required due to excessive lint from carpeting,
bedding material, et cetera. It is imperative that
control compartments, burners and circulating air
passageways of the appliance be kept clean.
Only doors certified with the appilance shall be used.
Do not operate appliance with the glass
front removed, cracked or broken. Replace-
ment of glass should be done by a licensed
or qualified service person.
WARNING:
03/21/01 #250-6120

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents