Quadra-Fire QFP 30 Operation & Maintenance Manual page 21

Direct vent gas fireplace
Table of Contents

Advertisement

HORIZONTAL INSTALLATION (CONT.)
Step 4.
Position the horizontal vent termination in the center
of the 10" (254mm) square hole, run a bead of
non-hardening mastic around its outside edges, so
as to make a seal between it and the wall, attach
termination cap to the exterior wall with the four
wood screws provided. The arrow on the vent
cap should be pointing up. Figure 7. Insure that
proper clearances to combustible materials are
maintained.
FIG. 7
HOT
WALL THIMBLE
#942
NOTE:
(1)
The four wood screws provided should be replaced
with appropriate fasteners for stucco, brick,
concrete, or other types of sidings.
(2)
Vent terminal shall not be recessed into a wall
or siding.
(3)
If you are using Simpson DuraVent termination cap
#985 on a building with vinyl siding, a vinyl siding
standoff (Simpson Dura-Vent Part #950), should
be installed between the vent cap and the exterior
wall (Figure 8). Attach the vinyl siding standoff to
the horizontal vent termination. The vinyl siding
standoff prevents excessive heat from possibly
melting the vinyl siding material. Remove siding
from beneath area of standoff.
03/21/01 #250-6120
QFP 30 Direct Vent Gas Fireplace
WOOD
SCREW
PART HHW2 PART
841-0670 (Preferred)
or #985
Step 5.
Slide the stove and vent assembly (see Fig.
9 below) towards the wall, carefully inserting
the vent pipe into the vent cap assembly. It is
important that the vent pipe extend into the vent
cap a sufficient distance so as to result in a
minimum pipe overlap of 11⁄4" (32mm). Secure
the connection between the vent pipe and the
vent cap by attaching the two sheet metal strips
extending from the vent cap assembly into the
outer wall of the vent pipe. Use the two sheet
metal screws provided to connect the strips to the
pipe section. (Figure 9).
Note:
The attachment from the vent pipe to the vent cap
must be siliconed.
WALL THIMBLE
COVER PART 940
WALL THIMBLE
PART 942
1/4"
FOLD STRAP
SHEET METAL SCREW
WALL THIMBLE COVER/CEILING
FIRESTOP AS REQUIRED BY
LOCAL JURISDICTION
VINYL SIDING
FIG. 8
APPLY SEALANT
TO ALL FOUR
SIDES
SCREWS
BOLT HORIZONTAL TOP
TO VINYL STANDOFF
SCREWS
VINYL SIDING STANDOFF
WITH SIDING BENEATH
REMOVED
WALL
THIMBLE
STRAP
Page 21