BOMBARDIER 650 Operator's Manual page 116

Traxter series
Table of Contents

Advertisement

1
V01C3SZ
TRAXTER 5 SPEED — UNDER ENGINE
1. Cooling drain plug
Unscrew the bleeding screw on the
top of thermostat housing.
Drain the system completely and rein-
stall the drain plug.
Pinch hose between radiator and ther-
mostat housing with a large hose
pincher (P/N 529 032 500).
V04C0CY
TRAXTER CVT
_____________________
116
V03C03Y
TRAXTER 5 SPEED
Fill the radiator until the coolant comes
out by the thermostat housing hole.
Install the bleeding screw then re-
move the hose pincher.
Complete the radiator filling.
Check the level in the coolant reservoir
and refill if necessary.
Run engine at idle with the radiator
cap off. Slowly add additional coolant
if necessary.
At this point, wait until engine reaches
normal operating temperature. De-
press the throttle lever two or three
times; then add coolant if required.
Install radiator cap. Inspect all connec-
tions for leaks and check coolant level
in the reservoir.
Valve Adjustment
All Traxter's engines used hydraulic
lifters, valve adjustment is not re-
quired.
Spark Arrester
The muffler must be periodically
purged of accumulated carbon.