Kyocera ECOSYS M6026cidn Operation Manual page 289

Hide thumbs Also See for ECOSYS M6026cidn:
Table of Contents

Advertisement

Setup, Registration, and User Management > System Menu
2
System Menu/Counter.
Adjustment/Maintenance - Color Registration
Normal
1
Detail
< Back
3
Select the chart to be corrected.
System Menu/Counter.
Normal - Registration
MH-L
0
MV
0
MH-R
0
CH-L
0
Cancel
4
Press [+] or [-] to enter the values read from the chart.
System Menu/Counter.
Registration - MH-L
(I - A, 0 - 9)
Cancel
Press [+] to increase the value from 0 to 9. To decrease, press [-].
By pressing [-], the value changes from 0 to alphabetic letters, going from A to I. To move in
the reverse direction, press [+].
You cannot use the numeric keys to enter these values.
5
3
4
Repeat steps
and
6
Press [Start] after all values have been entered. Color registration begins.
System Menu/Counter.
Normal - Registration
MH-L
0
MV
0
MH-R
0
CH-L
0
Cancel
7
Press [OK] after color registration is complete.
10:10
1/1
10:10
1/3
Start
10:10
OK
to enter the registration values for each chart.
10:10
1/3
Start
9-32
System Menu/Counter.
Color Registration - Normal
2
Print Chart
Registration
10:10
1/1
End

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecosys m6526cidn

Table of Contents