Getting Start
Programming Outline

Command Programming

The Programming Command (Pro CMD) pairs a unique Programming Code. Sending commands to the Imager
is identical with Code Programming. A full command is formed by [Start Symbol "nls" + Pro CMD = Parameters].
There are 4 ways to program a command:
1.
"nls" + Pro CMD
E.g. [nls0100060], set RS232 transmit Baud Rate to 38400bps
2.
"nls" + Pro CMD = Decimal Parameter
It is used to define parameter, such as Min Message Length.
E.g. [nls0312040=10], select Sensor Mode Sensitivity to be 10
3.
"nls" + Pro CMD = Hex Parameter
It is used to program Prefix, Suffix, Stop Bits, CodeID, Message Length, and Message Intersection.
E.g. [nls0310000=0x0d0a], program Suffix to be CR/LF
4.
"nls" + Pro CMD = "Parameter"
Letters, digits and characters can be embraced by quotation mark as parameter.
E.g. [nls0300000="AUTO-ID"], program Prefix to be AUTO-ID