4.2.3 Power supply cable

1
To set up the power supply for the air conditioner,
lay a three-pole (positive-neutral-earth), power sup-
ply cable with a cross section of at least 2.5 mm
This cable must be connected at one end to the
differential cut-off switch previously placed inside
the distribution board of the vehicle, while the other
end must reach the opening on the roof. Let the
cable come out from the reinforcing frame by about
50 cm to allow easier connection to the air condi-
tioner [Fig. 6].
1
4
connection, always make sure that there is no
power inside the distribution board or at the
cable end.
The air conditioner must be powered from a sepa-
rate cable, which must be provided with a 10A fuse.
it can provide proper insulation under any con-
dition of use of the vehicle.