Telair Silent 7300H Installation And User Manual

Telair Silent 7300H Installation And User Manual

Hide thumbs Also See for Silent 7300H:

Advertisement

v.007 September 2008

Advertisement

Table of Contents
loading

Summary of Contents for Telair Silent 7300H

  • Page 1 v.007 September 2008...
  • Page 2 Via E. Majorana , 49 48022 Lugo (RA) ITALY “ CE” DECLARATION OF CONFORMITY in compliance with EC Machine Directive 89/392, appendix II A It is hereby declared that the air conditioner specified below has been designed and built in compliance with essential safety and health requisites as per the European Directive on Machine Safety.
  • Page 3: Table Of Contents

    CONTENTS INTRODUCTION ------------------------------------------------------------------------------------ page 4 Purpose and field of application of the manual----------------------------------------------- page 4 Key to symbols and definitions ------------------------------------------------------------------- page 4 General information --------------------------------------------------------------------------------- page 4 IDENTIFYING THE AIR CONDITIONER------------------------------------------------------ page 5 Components ------------------------------------------------------------------------------------------ page 5 ID plate ------------------------------------------------------------------------------------------------- page 5 Technical specifications---------------------------------------------------------------------------- page 6 TRANSPORT, HANDLING AND STORAGE ------------------------------------------------ page 6 Storage ------------------------------------------------------------------------------------------------- page 6...
  • Page 4: Introduction

    INTRODUCTION 1.2 Key to symbols and definitions Always consult this manual carefully Indicates risk of serious before carrying out any work on the injury or death and that the utmost care must conditioner. be taken. 1.1 Purpose and field of application of this manual Situation that might arise during the working life of a product, system or...
  • Page 5: Identifying The Air Conditioner

    Power supply voltage IDENTIFYING THE AIR CONDITIONER must never drop below 210 Vac and frequency must be stable at 2.1 Components (fig. 1) 50 Hz. Using the air conditioner at voltages other Ventilation grille than those indicated could compromise its Upper cover efficiency and damage the unit.
  • Page 6: Technical Specifications

    2.3 Technical specifications 3.3 Handling SILENT 7300 H Packaged air conditioners can be moved Power supply 230 V 50 Hz using standard means of lifting and transport. Consumption 4.5 Ampere The packs have spacers for insertion of Peak current 18 A (0.15 sec.) transpallet forks.
  • Page 7: Installation

    4.2 Installation Before installing the unit all the following electrical connections on the vehicle must be disconnected. • Positive battery lead. • Generator (where applicable). • Outdoor power socket. Failure to observe the above can lead to power discharges. Before climbing on top of the vehicle check that the roof is designed to be walked on.
  • Page 8: Opening A New Hole

    4.2.2 Opening a new hole Fix a reinforcement frame around the opening (fig. Choose a central area of the roof between two side members and trace the outline of a Use protective gloves and 395 mm square with a felt-tip pen (fig. 2 ref. goggles before using electrical tools or A) (fig.
  • Page 9: Positioning The Air Conditioner

    Working from inside the vehicle, shift the air conditioner until the four fixing threads are aligned with the square 400 x 400 mm Before making opening of the hole on the roof. electrical connections always make sure Line the four external sides of the connecting the power is disconnected inside the duct with adhesive insulating tape so that it adheres to the folded fixing edge (fig.
  • Page 10: Connecting The Power Lead

    Fold the two long sides of the connector duct (fig. 12) so that they are horizontally in contact with the horizontal surface of the tunnel. The resulting connection is shown in Fig.13. Incorrect tightening can damage the support base of the air conditioner, compromise the seal and cause loud noise inside the vehicle when 4.4 Connecting the power lead...
  • Page 11: Installing The Diffuser

    L. 25 mm (fig. 17) The manufacturer cannot be held liable for damage caused by improper use of the air conditioner. The SILENT 7300H air conditioner consists of nine main parts: • compressor, which circulates the coolant gas through the system.
  • Page 12: Preliminary Checks

    • The SILENT 7300H provides cold air during Do not spray water inside the air the summer months and hot air in winter. conditioner. • If the vehicle has been left in the sun for Remove the remote control battery if you...
  • Page 13: Information On The Remote Control

    5.5 Information on the Remote Control Fan speed Allows the user to select one of the three available fan speeds. • Point the remote control towards the internal unit of the conditioner. • There must be no obstructions between the remote control and the internal unit. •...
  • Page 14: Remote Control Display

    Cooling mode Wait at least 2 minutes 1) Press the On/Off key. between switching off and subsequent Mode 2) Press switching on so as not to damage the repeatedly until display compressor. Conditioning shows symbol 3) Select the desired temperature using Increase temperature Decrease temperature keys.
  • Page 15: Diffuser Display

    5.12 Cleaning the filters 5.11 Diffuser Display The diffuser has a display which also incorporates the remote control receiver. When the red light (Fig. 20 ref. A) next to the Periodically clean both diffuser filters: wash legend “Power” is on the air conditioner is with a neutral detergent only and dry them powered by the 230 Vac power supply.
  • Page 16: Troubleshooting

    to clean the air conditioner when it has remained idle for a long period. TROUBLESHOOTING • if, after cleaning the exchangers, the air conditioner still fails to return to its initial In the majority of cases poor air conditioner level of efficiency, then the coolant gas performance is caused by incorrect use as load must be checked.
  • Page 17: Maintenance

    MAINTENANCE 9.1 Routine maintenance All tasks requiring removal of air conditioner covers must – as with installation - be carried out by expert personnel Before carrying out any work on the air conditioner it is essential that you disconnect the 230 V power supply and wait for all its component parts to cool down.
  • Page 18: General Terms Of Warranty

    GENERAL TERMS OF WARRANTY Telair guarantees that its products are without faults or defects in their material and/or construction. The effects of the warranty are understood to be limited to the right to obtain replacement or repair free of cost of any part which should turn out to be defective, within 12 months from the date of purchase of the product and in Telair’s opinion.
  • Page 22 Pos./Code/Q.tà Descrizione/Description Dèsignation/Bezeichnung Denomination/Descripcion Coperchio superiore in plastica Capot supérieur en plastique Bovenste deksel van plastic 1 / 03476 / n. 1 Plastic top cover Oberer Deckel aus Kunststoff Tapa superior de plástico Coperchio dell’evaporatore Couvercle de l’évaporateur Deksel van de verdamper 2 / 03493 / n.
  • Page 23 Stoffilter 81 / 03510 / n. 2 Dust filter Staubfilter Filtro anti-polvo Coperchio trasparente con logo Couvercle transparent avec Doorzichtige deksel met Telair Telair logo Telair logo 82 / 03492 / n. 2 Transparent cover with Telair Transparenter Deckel mit...
  • Page 24 ESPAÑA - NAUCCA ACCESORIOS Y REPUESTOS ESPAÑA - NAUCCA CARAVANING, S.A. Calle Pallars, 141 - 143 4°B Poligono Industrial CAN ROQUETA 2 – Calle Can Lletget,2 E-mail: telair@telecogroup.com 08018 Barcelona España 08202 Sabadell (Barcelona) - España Tel. 093 3099537 - Fax. 093 4850700 www.telecogroup.com e-mail: miguelcampos@naucca.com...

Table of Contents