Page 1
AIR CONDITIONER Split 7000 MANUAL FOR INSTALLATION AND USER MANUAL ENGLISH V005-February 2005...
Page 2
This statement shall fail to be valid should any changes be made to the machine without our approval in writing. Machine: AIR CONDITIONER Model: ICEBERG SPLIT 7000 Serial Number ......... Directive of reference: Machine Directive (89/392/EEC) in the 91/31/EEC version.
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 TABLE OF CONTENTS FOREWORD ------------------------------------------------------------------------------------------------------ pag. 4 Purpose and scope of application of this manua ---------------------------------------------------------- pag. 4 Symbols and definitions ---------------------------------------------------------------------------------------- pag. 4 General information ---------------------------------------------------------------------------------------------- pag. 5 AIR CONDITIONER IDENTIFICATION --------------------------------------------------------------------- pag. 6 Components ------------------------------------------------------------------------------------------------------- pag.
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 FOREWORD 1.2 Symbols and definitions MANUAL Read this manual carefully This means you must be careful before carrying out any kind of operation on the air conditioner. to avoid serious consequences which could lead to the death or injury of people.
(6 and 10 mm). The hoses are connected to the units by quick coupling joints (which do not require any special tool). All the SPLIT 7000 conditioners have been designed to be fed using 230 VAC 50 Hz current. The feeding voltage must fall within the range of 205 VAC and 250 VAC, the steady frequency between 49 Hz and 51 Hz.
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 AIR CONDITIONER IDENTIFICATION 2.1 Components (Fig. 1) 2.2 ID plate A) 1 CONDENSER UNIT 1 Model B) 4 SILENT BLOCKS AND 4 BRACKETS 2 Machine code C) 1 SUCTION CONVEYOR 3 Serial number D) 1 EXTENSION 6 m TUBE D. 6 mm 4 Compressor and fan consumption E) 1 EXTENSION 6 m TUBE D.
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 2.3 Technical features SPLIT 7000 Refrigerating power 2,1 kW / 7200 BTU Number of fan speeds Feeding 230 V 50Hz Consumption 4,2 A Start-up current 23 A (0,15 sec.) Absorbed power 970 W Refrigerating gas...
(for Italy, it must be exclusively installed by Weight not including packaging. qualified and specially trained personnel). SPLIT 7000 4.2 Installation 25 kg for the condensing part 9 kg for the evaporating part Before installing, you must cut 3.3 Handling...
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 4.3 Installing the condenser unit 4.3.1 "A" type installation Condensing unit dimensions: The condenser unit air intake is from the side and the hot air exhausts from the bottom. Height: 210 mm Width: 363 mm (423mm with conveyor) 4.3.2 "B"...
Page 10
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 Should the condenser unit be installed outside the The metal container has been set up so as to let vehicle, do not place the air inlet hole against a wall, both gas pipes, the 2 extension cables and the 230 which could limit the passage of air.
Page 11
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 The extension cables and pipes are provided with Connect both extension cables to the relevant a sealing through bush Fig. 6 Ref. (1) which must connectors of the condenser unit, Fig. 7 Ref. (1) be fitted into each of the sockets Fig.
Page 12
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 Fit the through bushes into the socket and lock A damaged input cable them in place using the plastic nuts provided. should only be replaced by the Let the supply cable out locking the through bush in manufacturer or its authorised after-sale place on the steel plate socket Fig.
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 4.4 How to fasten the condenser unit Always close the condensing unit completely before starting the air The condenser unit may be installed either conditioner. If the conditioner is run with one suspended on two brackets (not provided) on the of the condensing unit lids open, the gas outside of the vehicle Fig.
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 INSTALLING THE EVAPORATING (AERATOR) UNIT of the opening; if necessary, drill a hole on the side to let through the power cables and refrigerating gas pipes. The evaporator unit may be installed in either of two ways: 5.3 Positioning the evaporating unit using the ventilation holes (rooflight apertures)
Page 15
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 direction of the vehicle, while the rear holes Fig. 13 prevent any condensate forming inside the Ref. (2) face the rear of the vehicle. vehicle while the equipment is working. The arrow on Fig. 13 shows the driving direction of the vehicle.
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 30 and 60 mm. With thicker roofs, a larger conveyor Apply the diffuser to the conveyor. Make sure that will be required. the aluminium tunnel is properly placed at the very centre of the diffuser. Do not crush the sealing liner too much: it must not be less than 12 mm thick.
Fig. 19. speed fan. The SPLIT 7000 air conditioner can provide cool air in summer and warm air in winter. Before starting up the air conditioner - after a long period during...
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 6.4 Ventilation The air conditioner is provided with an environment thermostat having a If you want to circulate air inside the vehicle without minimum working temperature of 16°C. heating or cooling, proceed as follows. Below this temperature, the thermostat does not enable operation of the compressor.
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 6.8 Troubleshooting 6.6 Turning off If the air conditioner fails to work properly, this usually To turn the air conditioner off, set the switch Fig. 20 will not be due to a fault but simply to improper use. Ref.
SPLIT SPLIT SPLIT SPLIT SPLIT 7000 Take off the outside lid and spray a specific detergent on the heat exchangers (evaporator and 6) The air conditioner has a poor yield: condenser) and rinse with water to remove all dirt. • if the air conditioner has a poor yield, you must clean the air filter, the condenser and the evaporator, using specific detergents.
The warranty shall be valid only if the customer is able to show a document evidencing the date of purchase (invoice or receipt). This document must be kept whole and must be submitted to the Telair after-sales centre when asking for operation under warranty.