Telair SILENT BIPOWER 7000H Manual For Installation And User Manual

Hide thumbs Also See for SILENT BIPOWER 7000H:

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SILENT BIPOWER 7000H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Telair SILENT BIPOWER 7000H

  • Page 2 European Directive on Machine Safety. This declaration is rendered null and void where the machine is modified without our written approval. Machine: AIR CONDITIONER Model: SILENT BiPower 7000H Serial n°: ......... Reference Directives: Machine Directive (89/392/EEC), version 91/31/EEC. Low Voltage Directive (73/23/EEC).
  • Page 3: Table Of Contents

    INDEX INTRODUCTION ------------------------------------------------------------------------------------ page 4 Purpose of this manual----------------------------------------------------------------------------- page 4 Key to symbols and definitions ------------------------------------------------------------------- page 4 General information --------------------------------------------------------------------------------- page 4 IDENTIFYING THE CONDITIONER------------------------------------------------------------ page 5 Components ------------------------------------------------------------------------------------------ page 5 ID plate ------------------------------------------------------------------------------------------------- page 5 Technical characteristics--------------------------------------------------------------------------- page 5 TRANSPORT, HANDLING AND STORAGE ------------------------------------------------ page 6 Storage ------------------------------------------------------------------------------------------------- page 6 Weight -------------------------------------------------------------------------------------------------- page 6...
  • Page 4: Introduction

    1.3 General information Information particular importance highlighted in bold type and accompanied by SILENT BIPOWER 7000H have been plan to information/warning symbols (see following you for being install to you on the roof of key). vehicles. They...
  • Page 5: Identifying The Conditioner

    Heating power Ventilation grid Type and quantity of coolant Top lid ID Plate Diffuser Air expulsion nozzle SILENT BiPower 7000H Air intake grid (2) CODE : 03146 S.N.041007468 (3) Fan switch Refrigerating yeld :…………1,85 KW Menu switch Voltage :…………12 Vdc / 230 Vac Thermostat switch Frequency :……………………50 Hz...
  • Page 6: Transport, Handling And Storage

    3.2 Weight Before installing the unit all the electrical connections on the Weight without packaging: vehicle must be disconnected. SILENT BiPower 7000H Kg 40,5 • Positiv battery lead • Generator (where available) 3.3 Handling •...
  • Page 7: Using The Existing Ventilation Port

    The air conditioner may be installed in one of two different ways: • by using a ventilation aperture already on the vehicle (ventilation port) • by opening a new hole. 4.2.1 Using the existing ventilation port This solution is practical as long as the port size is 395 x 395 mm [fig.
  • Page 8: Power Lead

    It is compulsory for the air conditioner to be powered via a separate line protected by a 10 A magneto-thermal cut-out switch. 4.2.4 Power lead 12 Vdc To power the air conditioner it is necessary to connect it up with a red-black power lead having a minimum cross-section of 25 mm 2 .
  • Page 9: Connecting The Power Lead

    the airtight seal and cause loud noise during use. of slow-drying sealant around the rim of the aperture. Bring the air conditioner onto the roof [fig. 7 ref. 2] and, without scraping it, position it over 4.4.1 Connecting the power lead 230 Vac the 40 x 40 cm opening previously lined with sealant.
  • Page 10: Installing The Diffuser

    Check that the power lead is not excessively long as it could obstruct the intake grille. ISTRUCTION FOR USE 5.1 Introduction manufacturer 4.4.2 Connecting the power lead 12 Vdc cannot be held liable for damage caused by improper use of the air conditioner. Link the two “+ –“...
  • Page 11: Instructions For Us

    The SILENT BIPOWER air conditioner is 5.4 Switching on able to run at both 12 Volts (battery) and at 230 Volts (power mains). The 12 Volt or 230 To switch the air conditioner on Volt power supply is selected by a special press the on/off key [fig.
  • Page 12: Setting Fan Speed Thermostat

    that same speed. If, instead, fan speed is set thermostat does enable compressor: this prevents ice forming to AUT, the control panel step by step inside the unit. Fans and the heating function remain enabled. [fig. 12] automatically selects the most appropriate fan speed in consideration of the 5.5 Display [fig.12 rif.5] temperature setting and the temperature in...
  • Page 13: Heating Mode

    10. Do not insert objects into ventilation intakes. In this case, as long as ambient temperature remains below the 16°C threshold, only the fans work; the compressor is shut down. 11. If the air conditioner receives any hard knocks have it checked by specialised personnel before using it again.
  • Page 14: Disposal

    • set temperature higher than ambient temperature. MAINTENANCE 3) The condenser fan is not working • check that the condenser fan is not structed 8.1 Routine maintenance by foreign bodies. 4) Heating does not work • check that set temperature is higher than All tasks requiring removal of air ambient temperature.
  • Page 20 Pos/Code/Q.tà Descrizione/Description Dèsignation/Bezeichnung Denomination/Descripcion Coperchio superiore Couvercle supérieur Bovenste afdekking 1 / 02975 / n.1 Top lid Obere Abdeckung Tapa superior Couvercle de l'unité Coperchio evaporante Afdekking verdampingsunit d'évaporation 2 / 02976 / n.1 Cooler lid Abdeckung Verdunster Tapa unidad de evaporacion Evaporatore Unité...
  • Page 21 Pos/Code/Q.tà Descrizione/Description Dèsignation/Bezeichnung Denomination/Descripcion Compressore rotativo Compress. rotatif Roterende compressor 21 / 02984 / n.1 Sliding-vane compressor Kapselkompressor Compresor rotatorio Piastrina tubi sup Plaquette serre-tube Afdekplaatje buisdoorvoers 22 / 03110 / n.1 Verschlussplatte Fairlead pipe Chapa cierre pasatubes Röhredurchführung Piastrina tubi inf Plaquette serre-tube Afdekplaatje buisdoorvoers 23/ 03062 / n.1...
  • Page 22 Pos/Code/Q.tà Descrizione/Description Dèsignation/Bezeichnung Denomination/Descripcion sonde anti-givrage pour la Unité Sonda Antighiaccio Evaporatore anti-icing sonde voor Verdamper d'évaporation 47 / 03087 / n.1 enteisende Prüfspitze zur punta de prueba antiescarcha anti-icing probe for Cooler Verdunster para el Evaporador Pressostato Pressostat Drukverschilschakelaar 48 / 01619 / n.1 Pressure switch Druckschalter...
  • Page 23 Pos/Code/Q.tà Descrizione/Description Dèsignation/Bezeichnung Denomination/Descripcion Relè MAC-15D 12Vdc Relais MAC-15D 12vdc Relais MAC-15D 12vdc 68 / 02888 / n.1 RelayMAC-15D 12vdc Relais MAC-15D 12vdc Rele MAC-15D 12vdc Rele' 12V 40 Amp. Relais 12V 40A Relais 12V 40 Amp. 69 / 00513 / n.1 Relay 12V 40 Amp Relais 12V 40 Amp.
  • Page 24: General Terms Of Warranty

    GENERAL TERMS OF WARRANTY Telair guarantees that its products are without faults or defects in their material and/or construction. The effects of the warranty are understood to be limited to the right to obtain replacement or repair free of cost of any part which should turn out to be defective, within 12 months from the date of purchase of the product and in Telair’s opinion.
  • Page 25 NOTES: ....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Page 26 NOTES: ....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Page 27 NOTES: ....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Page 28: Air Conditioner

    Mobil. 06 78262186 Mobil. 06 07012634 e-mail: bleysetd@club-internet.fr - jp.bleysetd@club-internet.fr ESPAÑA - NAUCCA ACCESORIOS Y REPUESTOS ESPAÑA - NAUCCA CARAVANING, S.A. E-mail: telair@telecogroup.com Calle Pallars, 141 - 143 4°B Poligono Industrial CAN ROQUETA 2 – Calle Can Lletget,2 08018 Barcelona España www.telecogroup.com Tel.

Table of Contents