Via E. Majorana , 49 48022 Lugo (RA) ITALY “ CE” DECLARATION OF CONFORMITY in compliance with EC Machine Directive 98/37/EC It is hereby declared that the air conditioner specified below has been designed and built in compliance with essential safety and health requisites as per the European Directive on Machine Safety. This declaration is rendered null and void in the event of incorrect assembly, improper use or modifications made to the machine without our written approval.
CONTENTS INTRODUCTION ----------------------------------------------------------------------------------- page 4 Purpose and field of application of the manual ---------------------------------------------- page 4 Key to symbols and definitions ------------------------------------------------------------------ page 4 General information -------------------------------------------------------------------------------- page 4 IDENTIFYING THE AIR CONDITIONER ----------------------------------------------------- page 5 Components ----------------------------------------------------------------------------------------- page 5 ID plate ------------------------------------------------------------------------------------------------ page 5 Technical specifications --------------------------------------------------------------------------- page 6 TRANSPORT, HANDLING AND STORAGE ------------------------------------------------ page 6...
INTRODUCTION 1.2 Key to symbols and definitions Always consult this manual carefully Indicates risk of serious before carrying out any work on the injury or death and that the utmost care must conditioner. be taken. 1.1 Purpose and field of application of this manual Situation that might arise during the working life of a product, system or...
IDENTIFYING THE AIR CONDITIONER 2.1 Components (fig. 1) 2.2 ID plate Ventilation grille Model Upper cover Serial number Machine body Type of electrical power Technical specifications label Cooling capacity Connector duct Heating capacity Air/conditioner block tunnel Type and quantity of coolant gas Diffuser Air flow rate Adjustable air outflow vents...
3.2 Weight 2.3 Technical specifications Weight, packaging excluded: SILENT 7300 H SILENT 7300 H 34 kg Power supply 230 V 50 Hz Consumption 4.5 Ampere Peak current 18 A (0.15 sec.) 3.3 Handling Absorbed power, cooling 900 Watt Absorbed power, heating 920 Watt Packaged air conditioners can be moved Cooling capacity...
4.2 Installation Before installing the unit all the following electrical connections on the vehicle must be disconnected. • Positive battery lead. • Generator (where applicable). • Outdoor power socket. Failure to observe the above can lead to power discharges. Before climbing on top of the vehicle check that the roof is designed to be walked on.
4.2.2 Opening a new hole Fix a reinforcement frame around the Choose a central area of the roof between opening (fig. two side members and trace the outline of a 395 mm square with a felt-tip pen (fig.2) and (fig. 4 ref. 1). Use protective gloves and goggles before using electrical tools or handsaws.
Before making Working from inside the vehicle, shift the air electrical connections always make sure conditioner until the four fixing threads are the power is disconnected inside the aligned with the square 395 x 395 mm distribution board and that the wire ends opening of the hole on the roof.
Fit the air/block tunnel with the supplied Fold the two long sides of the connector duct screws (fig. 10 . It is important to attach the (fig. 12) so that they are horizontally in screws according to a driving torque of contact with the horizontal surface of the 2 Nm, that is, 0.2 kgm.
L. 25 mm (fig. 17) The manufacturer cannot be held liable for damage caused by improper use of the air conditioner. The SILENT 7300H air conditioner consists of nine main parts: • compressor, which circulates the coolant gas through the system.
• The SILENT 7300H provides cold air during Remove the remote control battery if you the summer months and hot air in winter. do not intend to use the conditioner for a If the vehicle has been left in the sun for long period.
5.5 Information on the Remote Control • Point the remote control towards the internal unit of the conditioner. • There must be no obstructions between the remote control and the internal unit. • Do not drop or throw the remote control. •...
5.7 Remote control display (fig. 19) Cooling mode 1) Press the On/Off key. 2) Press the Mode key repeatedly until display shows the Conditioning symbol 3) Select the desired temperature using the Increase temperature or Decrease temperature keys. 4) Press the Fan speed key repeatedly until the desired fan speed appears.
5.11 Diffuser Display The diffuser has a display which also SAFETY REGULATIONS incorporates the remote control receiver. • Always use properly earthed power sockets with differential safety switches. • Never use the air conditioner near flammable liquids. • Do not use the air conditioner for purposes other than those stated by the manufacturer.
TROUBLESHOOTING 5) A ir conditioner efficiency is poor • conditioner working In the majority of cases poor air conditioner inefficiently it is necessary to clean the air performance is caused by incorrect use as filter, condenser and evaporator using opposed to actual malfunctions. For example: specific detergents.
MAINTENANCE 9.1 Routine maintenance All tasks requiring removal of air conditioner covers must – as with installation - be carried out by expert personnel Before carrying out any work on the air conditioner it is essential that you disconnect the 230 V power supply and wait for all its component parts to cool down.
GENERAL TERMS OF WARRANTY TELAIR guarantees its products against any construction material and/or manufacturing faults and defects. The right to warranty cover for new products is valid for a period of 24 months from the time of handing over to the end user, or for a maximum of 1000 operating hours, whichever limit is reached first.
Page 22
Pos/Code/Q.tà Descrizione/Description Dèsignation/Bezeichnung Denomination/Descripcion Coperchio superiore Couvercle supérieur Bovenste afdekking 1 / 03476 / n.1 Top lid Obere Abdeckung Tapa superior Coperchio evaporante Couvercle de l'unité d'évaporation Afdekking verdampingsunit 2 / 03493 / n.1 Cooler lid Abdeckung Verdunster Tapa unidad de evaporacion Evaporatore Unité...