Summary of Contents for Telair SPLIT BIPower 7000H
Page 2
This statement shall fail to be valid should any changes be made to the machine without our approval in writing. Machine: AIR CONDITIONER Model: SPLIT BIPower 7000H Serial Number …………………… Directive of reference: Machine Directive (89/392/EEC) in the 91/31/EEC version.
FOREWORD 1.2 Symbols and definitions Read this manual carefully before carrying out any kind of operation on the air This means you conditioner. must be careful to avoid serious consequences which could lead to the death or injury of people. 1.1.
CONDENSER UNIT which installed outside the vehicle, inside the double bottom, inside the garage or a bench or a cabinet. The purpose of this unit is to drive our hot air during the conditioning stage and cold air during the heat pump stage.
Weight not including packaging. 4.2 Installation Split BiPower 7000H condensing part ..kg 45 Split BiPower 7000H evaporating part .kg 13,5 Before installing, you 3.3 Handling must cut off all the power supply to the vehicle.
4.3 Installing the condenser unit could be sucked in again by the opening Fig. 03 Ref. (1). When you install the condenser unit, remember it must always communicate towards the outside via at least two openings Fig. 02 Ref. (1) and (2). In fact, the condenser unit sucks air in from the outside via the opening Fig.
After having prepared the area of installation of The extension cables and the feeding cable the condenser unit, you should connect the gas are provided with fairleads which must be housed in the suitable seat fig. 07 pipes and the extension cables, before finally fastening the unit in place.
shielded terminal board – to the power supply cable which must previously be let out by positioning the fairlead Fig. 08 4.3.4 12 Vdc power supply of the condenser unit In order to power-supply the condenser unit, it is necessary to arrange a red cable (+) and a black cable (-).
Fig. 13 Special attention should paid when positioning the silent-blocks which must be subject to compression Fig. 12 and Fig. 13 4.6 How connect pipes condenser unit Screw out the plug Fig. 14 Ref. 1 of the service low pressure valve Fig. 14 Ref. 2 Screw out the plug Fig.14 Ref.5 of the service high pressure valve Fig.
INSTALLING THE EVAPORATING (AERATOR) UNIT Keep the plugs of Fig. 15 Ref. 1 and Ref. 3 together with the user manual. The evaporator unit may be installed in either of Screw down the fitting integral to the low two ways: pressure pipe on the service low pressure valve Fig.
5.2 Opening a new hole Place a reinforcing frame (Fig. 19) along the On the roof, chose an central area between two profile of the opening. stanchions and use a felt pen to mark off a square measuring 395 mm on each side Fig. 18 Ref.
Page 14
while the rear holes Fig. 20 Ref. 2 follow the rear of the vehicle. The arrow on Fig. 20 shows the driving direction of the vehicle. Place the outside unit on the roof as shown on the figure and centre it over the 39,5 x 39,5 hole.
SETTING AT WORK will then be on the aluminium conveyor, then drill the holes with a 3 mm drill. 6.1 Foreword The SPLIT BIPOWER 7000H air conditioner consists of four basic sections: • compressor: this makes the refrigerating gas circulate inside the system;...
The SPLIT BIPOWER 7000H air conditioner is able to run at both 12 Volts (battery) and at 230 Volts (power mains). The 12 Volt or 230 Volt power supply is selected by a special circuit Fig.
6.3 Preliminary checks Before switching on the air conditioner for the very first time: • Check that condensate drainage holes are unobstructed. • Check that power voltage and frequency are as indicated in the previous section. • Check that air flow through relative ducts and vents is unobstructed.
6.4.1 Switching on 6.4.3 Setting fan speed To switch the air conditioner on press the on/off key (Fig. 31 ref. 3) and at the same time, the Press the speed key display is active Fig. 31 Rif. 1 If pressed once the display shows the fan speed setting: this is shown for a few seconds before After switching on the the display reverts to ambient temperature (TA).
The outdoor limit Correct use of the thermostat is very important. If you set a temperature operation temperature much lower than outdoor conditioner is – 5 °C. temperature (more than 8°C lower) you run the risk of falling ill (catching colds etc.) 6.4.7 Switching off and energy consumption increases.
5) The air conditioner has a poor yield: • If the air conditioner has a poor yield, you TROUBLESHOOTING must clean the air filter, the condenser and the evaporator, using specific detergents. We suggest washing the air conditioner If the air conditioner fails to work properly, this before using it, after a long period of time usually will not be due to a fault but simply to during which it has not been used.
MAINTENANCE Maintenance operations In order to ensure proper efficiency of the air conditioner, once a year you must carry out a thorough cleaning of the condenser, or have a technician carry it out. Before accessing the air conditioner, you must by all means disconnect the 230 and 12 Volt power supply and wait for every part to cool down.
GENERAL TERMS OF WARRANTY Telair guarantees that its products are without faults or defects in their material and/or construction. The effects of the warranty are understood to be limited to the right to obtain replacement or repair free of cost of any part which should turn out to be defective, within 12 months from the date of purchase of the product and in Telair’s opinion.