Silent 7300H Working manual ELECTRONIC CONTROL BOARD: CONNECTIONS Control unit components (Ⅰ)This control unit mainly consists of: a control panel, display and receiving board, infrared remote control etc. The electronic control board controls the following elements: Compressor, four-way valve, external fan, internal fan, control probe.
Silent 7300H Working manual Fault and Auto-diagnostic Display This control device detects any type of fault by sampling and checking; the faults are shown on a display unit. The faults are described and displayed in the following table: Fault Displayed error code Ambient temperature sensor fault……………………………..E1...
Silent 7300H Working manual 3.External fan working condition: In the cooling mode, the external fan will turn in synch with the compressor. 4. Internal fan working condition: a) The internal fan rotation speed can be set to high, medium, low and automatic.
Page 7
Silent 7300H Working manual 3) External fan working condition: a) When the compressor stops, the external fan also stops. b) During heating for condenser defrosting, the compressor starts and the external fan is stopped. c) As a protective measure against evaporator overheating, the external fan is stopped.
Page 8
Silent 7300H Working manual 7) Protection in case of failure to Heat (ERROR E4): After 5 minutes of continuous compressor operation, the temperature difference between Tp and Tr must be greater than or equal to 3°C. If the temperature difference cannot be achieved after the first minute of continuous compressor operation, the temperature display begins to flash.
Silent 7300H Working manual AUTOMATIC OPERATION MODE 1) How to access the automatic operation mode: Access to the automatic operation mode can be obtained by working the emergency switch or by using the remote control; the control unit will automatically select heating, cooling or ventilation according to the vehicle inside temperature.
Silent 7300H Working manual AUTO DIAGNOSTICS 1) When the air conditioner is installed for the first time, by pressing and holding down the emergency button you will cause the control unit to activate auto-diagnostics procedures. The operations carried out are the...
Page 14
Silent 7300H Working manual Pos./Code/Q.tà Descrizione/Description Dèsignation/Bezeichnung Denomination/Descripcion Coperchio superiore in plastica Capot supérieur en plastique Bovenste deksel van plastic 1 / 03476 / n. 1 Plastic top cover Oberer Deckel aus Kunststoff Tapa superior de plástico Coperchio dell’evaporatore Couvercle de l’évaporateur Deksel van de verdamper 2 / 03493 / n.
Page 15
Silent 7300H Working manual Pos/Code/Q.tà Descrizione/Description Dèsignation/Bezeichnung Denomination/Descripcion Condotto uscita aria Conduite de sortie de l’air de Luchtuitlaatkanaal uit de dall'evaporatore l’évaporateur verdamper 34 / 03498 / n. 1 Duct for air outlet from Luftausgangskanal aus Conducto salida aire del...
Page 16
Silent 7300H Working manual WORKING MANUAL ITALY Via E.Majorana 49 48022 LUGO( RA ) Tel. + 39 0545 25037 Fax.+ 39 0545 32064 E-mail: telair@telecogroup.com www.telecogroup.com...