Gestetner B003 Service Manual page 607

Table of Contents

Advertisement

Rev. 09/2002
DESCRIPTION OF MODIFICATION
The following items have been fixed:
1. The controller freezes if disconnected while data
containing the Readback command is being printed out
with ftp/rsh.
2. Display corrected for when the operator tries to execute
Spool Printing Job List with SmartNetMonitor for Admin
on the A-C2/R-C2:
Previous: "Spool printing is not available. Active spool
printing from the device or related software"
New: "Error 404"
3. The Fax Management Tool cannot be used while any of
the NIB setting(s) are being changed.
4. The parameters of sysLocation and sysContact cannot
be set correctly using the snmp command with telnet.
5. The controller freezes when a non-existent file is
specified for rcp transmission.
6. Cannot connect to Novel NDS (GFPR #RC02010007):
The nearest NetWare Server informs the NIB of the
alternate NetWare Server address, where the NDS
replica is stored, however the NIB is unable to interpret
the message.
Change in Specification:
1.
SNMP vulnerability
SNMP security vulnerabilities reported by CERT on
Feb.12, 2002 has been tested using the PROTOS c06-
snmpv1 test suite and we have verified the fixes.
-CERT: http://www.cert.org/advisories/CA-2002- 03.html
-PROTOS c06-snmpv1 test suite
:
http://www.ee.oulu.fi/research/ouspg/protos/testing/c06/snmp
v1/
2. Some reserved (unused) TCP ports that were open have
been closed, e.g. FTP.
SM
FIRMWARE
LEVEL
G0585921 G
4-17
SOFTWARE HISTORY
FIRMWARE
VERSION
1.81
B003/B004/B006/B007