SP5
Mode Number
5501*
2*
Original Count Alarm
5504*
Jam Alarm
5505*
Error Alarm
5507*
1*
Paper Supply Alarm
2*
Staple Supply Alarm
3*
Toner Supply Alarm
128*
Others
132*
A3
133*
A4
134*
A5
141*
B4
142*
B5
160*
DLT
164*
LG
166*
LT
172*
HLT
5508*
CC Call
1*
Remain of Jam
(Unattended Jam)
SM
SERVICE PROGRAM MODE
Function and [Setting]
Sets the alarm to sound after the specified total
number of originals goes through the ARDF.
0: Disabled, 1: Enabled
0: No alarm sounds
1: Alarm sounds after the number of originals
passing through the ARDF ≥ 10,000
Sets the alarm to sound for the specified jam level
(document mis-feeds are not included). DFU
[0~3 / 3 / 1 step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
Sets the error alarm level. Japan only
[0~255 / ACV / 100 copies per step]
Switches the control call on/off for the paper
supply. DFU
0: Off, 1: On
0: No alarm.
1: Sets the alarm to sound for the specified
number transfer sheets for each paper size
(A3, A4, B4, B5, DLT, LG, LT, HLT)
Switches the control call on/off for the stapler
installed in the finisher. Japan only
0: Off, 1: On
0: No alarm
1: Alarm goes off for every 1K of staples used.
Switches the control call on/off for the toner end.
DFU
0: Off, 1: On
If you select "1" the alarm will sound when the
copier detects toner end.
The "Paper Supply Call Level: nn" SPs specify
the paper control call interval for the referenced
paper sizes. DFU
[00250 ~ 10000 / 1000 / 1 Step]
Switches the control call on/off for an unattended
jam. DFU
0: Off, 1: On
If you select "1", the alarm sound if a jam is left
unattended for 15 minutes.
5-31
B003/B004/B006/B007

Advertisement

Table of Contents
loading

This manual is also suitable for:

B004B006B007350245023502p ... Show all

Table of Contents