Replacement Of Capstan Motor - Sony DSR-570WS Service Manual

Digital camcorder
Hide thumbs Also See for DSR-570WS:
Table of Contents

Advertisement

6-28. Replacement of Capstan Motor

Mode: Unthreading end
Replacement Flowchart
Removal of SV-213 board
Removal of HN-227 board
Replacement of capstan motor
Capstan FG DUTY adjustment
Tracking adjustment
Check after tracking adjustment
Check of self-recording tape playback
Removal
1. Remove the SV-213 board.
(Refer to Section 2-9-8.)
2. Remove the HN-227 board.
(Refer to Section 2-9-9.)
3. Remove the two screws shown in the figure, and
remove the capstan motor and spacer.
Attachment
4. Attach the new capstan motor and spacer in the
reverse order of step 3.
5. Attach the parts removed in the reverse order of
steps 1 and 2.
Check/Adjustment
6. Perform the capstan FG DUTY adjustment at
Menu M601. (Refer to Section 10-2-1.)
7. Perform the tracking adjustment.
(Refer to Section 7-3.)
8. Perform the check after tracking adjustment.
(Refer to Section 7-4.)
9. Perform the check of self-recording tape
playback. (Refer to Section 7-5.)
6-38
Spacer
(Thickness : 100um)
Capstan motor
Screws
DSR-570WS/570WSP V1

Hide quick links: