6. Adjust the RF waveform on the exit side to
become flat by turning the flange of the TG-5
guide.
7. Be sure to finish the adjustment by turning the
flange of the TG-5 guide clockwise.
m
. If turning the flange of the TG-5 guide clockwise
too much, return the flange back to the original
position and re-start the adjustment. Finish it by
turning the flange clockwise.
. Do not turn the tilt adjustment screws of the TG-4
and TG-5 guides.
8. Set the REV search mode, and check that there
are no curls formed at the lower flange of the
TG-2 guide. If curled, perform steps (1), (2)
and (3).
(1) Rotate the upper flange of the TG-2 guide
in the clockwise direction to remove the
curls.
(2) Rotate the upper flange of the TG-3 guide
in the counterclockwise direction by 180d,
and check that the tape rises. Then return
the nut to its original position.
(3) If not certified the specification, Perform
the step 4 and step 5.
DSR-570WS/570WSP V1
7-11