Rf System Adjustment; Rec Current Adjustment - Sony DSR-570WS Service Manual

Digital camcorder
Hide thumbs Also See for DSR-570WS:
Table of Contents

Advertisement

10-3. RF System Adjustment

10-3-1. REC Current Adjustment

n
Be sure to perform this adjustment when the RP-91 board
is repaired and recording amplifier (IC777) or EEPROM
(IC770) on the board is replaced.
Be sure not to perform this adjustment when replacing the
RP-91 board.
1. Set the unit in maintenance menu, and select Menu No.
700.
(1) While pressing the SHIFT button, press the MENU
button, then release the SHIFT button, and press the
MENU button for more than one second.
The following message is displayed on the LCD screen.
(In the following description, an underlined part
indicates a portion of the display which is blinking.)
(2) Press the RESET (MENU SET) button once so that
"oFF" blinks.
The following message is displayed on the LCD screen.
Each time the RESET (MENU SET) button is pressed,
"600" and "oFF" will blink alternately.
(3) Press the ADVANCE button once, and select "on."
The following message is displayed on the LCD screen.
Each time the ADVANCE button is pressed, "on" and
"oFF" will blink alternately.
(4) Press the RESET (MENU SET) button once.
The following message is displayed on the LCD screen.
Each time the RESET (MENU SET) button is pressed,
"600" and "on" will blink alternately.
DSR-570WS/570WSP V1
(5) Press the ADVANCE button several times and display
Menu No. 700.
The following message is displayed on the LCD screen.
2. Press the RESET (MENU SET) button.
3. Check that the following message is displayed on the
LCD screen:
4. Press the RESET (MENU SET) button.
5. Check that the following message is displayed on the
LCD screen:
6. Press the RESET (MENU SET) button.
7. Check that the following message is displayed on the
LCD screen:
If the following message is displayed on the LCD
screen, exit from Menu No. 700, and perform from step
1 again.
If the following message is still shown on the LCD
screen, check whether the unit is normal or not.
X X: E0 → Cannot save data
8. Press the MENU button, and exit from the maintenance
menu.
The state before the maintenance menu indication will
be displayed on the LCD screen.