C. Optional LED Lighting Circuit
For models with LED lighting option only.
LIGHT
APPLIANCE
CONTROL
CONTROL
YELLOW
ORANGE
GREEN
BLK
NOTE: The chart below show the colors
produced when light control is wired and
orientated as shown in this wiring diagram.
SWITCH TRIPPED
YELLOW
ORANGE
GREEN
YEL/ORG/GRN
YEL/ORG
ORG/GRN
YEL/GRN
Figure 8.7 LED Wiring Diagram
6 LEAD WALL CONTROL WIRE
ON/OFF
RED
BRN
TO WIRE HARNESS
COLOR PRODUCED
GREEN
RED
BLUE
WHITE/CLEAR
YELLOW
PURPLE
LIGHT BLUE
Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
LED LIGHTBAR
ASSEMBLY
L.E.D CONTROL HARNESS
2 1
RED
BRN
PLUG IN
POWER SUPPLY
PLUG IN
NEUTRAL
HOT
JUNCTION BOX
NOTE: Harness wire colors are subject to change without
notice.
NOT USED FOR THIS MODEL