Securing And Leveling The Appliance - Heat & Glo RED60 Installation Manual

Installation and appliance setup
Hide thumbs Also See for RED60:
Table of Contents

Advertisement

B. Securing and Leveling the Appliance
WARNING! Risk of Fire! Prevent contact with:
• Sagging or loose insulation
• Insulation backing or plastic
• Framing and other combustible materials
Block openings into the chase to prevent entry of blown-
in insulation. Make sure insulation and other materials
are secured.
DO NOT notch the framing around the appliance
standoffs. Failure to maintain air space clearance may
cause overheating and fi re.
Figure 6.2 shows how to properly position, level and secure
the appliance. Nailing tabs are provided to secure the ap-
pliance to the framing members.
• Bend out the two nailing tabs on each side.
• Place the appliance into position.
• Keep nailing tabs fl ush with the framing. See Figure 3.4.
• Level the appliance from side to side and front to back.
• Shim the appliance as necessary. It is acceptable to use
wood shims underneath the appliance.
• Secure the appliance to the framing by using nails or
screws through the nailing tabs.
Figure 6.2 shows the fireplace installed on the floor.
However, this fireplace can be elevated off the floor
provided that the fi replace is properly supported by framing
materials and the ceiling clearances are maintained.
POSSIBLE LOCATIONS FOR VENT
TERMINATION OF ACTIVE CONVECTION
TECHNOLOGY
Figure 6.2 Proper Positioning, Leveling And Securing Of An Appliance
Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
Setting the Fireplace into the Framing
The left and right nailing tabs were designed as a means
to ensure the fi replace is mounted fl ush with the framing
materials.
Bend out all four nailing tabs. Screw or nail each nailing
tab to the adjoining framing material. Ensure that the one
inch air space clearance is maintained on the sides and
back of the fi replace. See Figure 6.3 and Figure 6.4.
NAILING
TAB
Figure 6.3 Nailing Tabs
Shipping Position
N o t e : A c t i v e C o n v e c t i o n
Technology must not pull air from
outside. Termination must draw air
from an interior room.
TERMINATION INTO INTERIOR ROOM
NAILING
TAB
Figure 6.4 Nailing Tabs
Installation Position
6 IN. X 5.5 IN. REQUIRED
GRILLE PANEL
DUCT COLLAR
ASSEMBLY
43

Advertisement

Table of Contents
loading

Table of Contents