Electrical Information

A. General Information
WARNING! Risk of Shock or Explosion! DO NOT wire
110-120 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• Wire the appliance junction box to unswitched 110-
120 VAC. This is required for proper operation of the
appliance.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
• Low voltage and 110-120 VAC voltage cannot be shared
within the same wall box.
Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105º C rated wire. Wire must have high temperature
insulation.
Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
Junction Box Installation
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
1. Remove the one screw that secures the junction box
to the control tray panel.
2. Route the wire through the strain relief in the outer wrap
and down through the knockout located on top side of
the junction box. See Figure 8.1.
3. Make the connection inside the junction box to the 110-
120 VAC wire. Connect green to the ground nut, black
to black, and white to white.
4. To reattach the junction box, insert one end of the
junction box in the slot provided and securely screw the
other end of the junction box to the control tray panel.
KNOCKOUT
KNOCKOUT
Figure 8.1 Junction Box Detail
In the event that the junction box may need to be ac-
cessed or installed after fi nish methods have been ap-
plied, access is possible by removing the valve assembly
See Figure 8.1.
Accessories Requirements
• This appliance may be used with a wall switch or a wall
mounted thermostat.
Wiring for optional Hearth & Home Technologies ap-
proved accessories should be done at initial installation to
avoid reconstruction. Follow instructions that come with
those accessories.