Heat & Glo RED60 Installation Manual
Heat & Glo RED60 Installation Manual

Heat & Glo RED60 Installation Manual

Installation and appliance setup
Hide thumbs Also See for RED60:
Table of Contents

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Model:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
Installation Manual
Installation and Appliance Setup
Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
WARNING
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RED60 and is the answer not in the manual?

Questions and answers

Summary of Contents for Heat & Glo RED60

  • Page 1 See Table of Contents for location of additional Commonwealth appliance is not convertible for use with other of Massachusetts requirements. gases, unless a certifi ed kit is used. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 2: Table Of Contents

    H. Sheet Metal Refractory Instructions ....81 - PVK-80 for RED60 Model ..... . . 29 I.
  • Page 3: Installation Standard Work Checklist

    _____________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date) = Contains updated information. 2159-982 Rev. C 11/13 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 4: Product Specifi C And Important Safety Information

    • A 110-120 VAC circuit for this product must be pro- tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 6: Getting Started

    Call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 7: Framing And Clearances

    1826 70-1/8 1781 17-3/16 35-1/16 10-3/4 18-5/8 62-3/4 1594 9-1/2 68-1/8 1730 3-3/4 1-1/2 8-1/2 5-1/4 17-1/8 18-1/8 12-7/8 50-3/4 1289 2-1/4 3-5/8 Figure 3.1 Appliance Dimensions Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 8: Clearances To Combustibles

    45° TOP VENT ONE 90° ELBOW Inches 75-15/16 70-3/8 107-3/8 31-7/8 18-3/4 See Section D. Figure 5.6 & 5.7 Millimeters 1929 1788 2727 Figure 3.2 Appliance Locations Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 9: Constructing The Appliance Chase

    Opening Opening Opening to Ceiling Floor Flooring Appliance Appliance Appliance (Vent Pipe) (Height) (Depth) (Width) Inches 18-1/4 70-3/8 Millimeters 1295 1788 1092 Figure 3.3 Clearances to Combustibles Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 10 NAILING TABS BOTH SIDES Figure 3.4 Nailing Tab Locations Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 11: Termination Location And Vent Information

    Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 4.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 12: Chimney Diagram

    Figure 4.3 Minimum Clearances for Termination • Vinyl protection kits are suggested for use with vinyl siding. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 13: Approved Pipe

    • When penetrating a combustible ceiling, a ceiling fi restop must be installed. • Horizontal runs of vent do not require vertical rise; horizontal runs may be level. Vertical 8-1/2 in. Horizontal Figure 4.4 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 14: Installation Instructions And Venting Information - Pvi-Dvp

    Disconnect electrical power supply before making wiring connections. g. Venting of more than one appliance in a common vent system is prohibited. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 15 ACCESS PANEL 11-5/8 IN. 13 IN. 18-7/8 IN. SIDE 30-11/16IN. 1/2 IN. CLEARANCE 1 IN. CLEARANCE Figure 4.6 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 16 Figure 4.10 PVI-DVP Mounted to Vertical Surface Figure 4.8 Mount the Catch Plate Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 17 2 in. 1/2 IN. MAX. FROM BACK OF OPEN AIR COVER LOUVERED OR OPEN AIR WALL COVER SHEETROCK Figure 4.12 PVI-DVP Mounted with Fresh Air Access Figure 4.14 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 18 Connect the brown wire to the brown wire coming from the 8K1-PVI. c. Connect the red wire to the red wire coming from the 8K1-PVI. Figure 4.17 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 19 See Figure 4.20 for the location on the vert- Figure 4.20 Vacuum Switch Location - Horizontal/Vertical Orientation Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 20: Operating Instructions

    4. Turn the fi replace ON/OFF switch to "OFF" to turn off the burner and the power vent. REMOVE NUTS (5) Figure 4.23 Motor Service Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 21: Vent Diagrams

    = 80 ft. (24.4 m) Maximum position except V WARNING! Risk of fi re and burns! DO NOT install PVI-DVP with the access panel facing upward. Over- heating may occur. Figure 4.24 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 22 V WARNING! Risk of fi re and burns! DO NOT install PVI-DVP with the access panel facing upward. Over- heating may occur. INSTALLED HORIZONTALLY Figure 4.25 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 23 Total V + Total H = 40 ft. (12.2 m) Maximum 4 ft. 1.2 m 60 ft. 18.3 m TOTAL V + TOTAL H = 60 ft. (18.3 m) Maximum Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 24 Top Vent - Vertical Termination No Elbows = 8 ft. Min. (2.4 m) = 50 ft. Max. (15.2 m) Figure 4.27 Vertical Vent Maximum Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 25 Note: PVI-DVP can be located in any position except V WARNING! Risk of fi re and burns! DO NOT install PVI-DVP with the access panel facing upward. Over- heating may occur. Figure 4.28 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 26 1.2 m 60 ft. 18.3 m Total V + Total H = 40 ft. (12.2 m) Maximum TOTAL V + TOTAL H = 60 ft. (18.3 m) Maximum Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 27 (Total V + Total H) of 10 ft. 22 ft. - (6 ft vertical drop x 2*) = 10 ft. Figure 4.30 Power Vent Positioned Before Vertical Drop Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 28 (Total V + Total H) of 24 ft. 34 ft. - (5 ft vertical drop x 2*) = 24 ft. Figure 4.31 Power Vent Positioned After Vertical Drop Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 29: Installation Instructions And Venting Information - Pvk-80 For Red60 Model

    Firestop 4. Disconnect electrical power supply before making wiring connections. WALL 5. VENTING OF MORE THAN ONE APPLIANCE IN A COMMON VENT SYSTEM IS PROHIBITED. Figure 4.33 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 30 Fasten the other end of each brace to the outside wall. See Figure 4.36. WIRE ACCESS HOLE Figure 4.37 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 31 Do not change this setting. WARNING! Risk of Overheating! DO NOT change ex- haust control lever setting! Glass failure will occur. WIRES FROM POWER VENT Figure 4.38 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 32 Figure 4.39 RED60 PVK-80 Wiring Diagram with IntelliFire Plus Pilot Ignition CONTROL LEVER - REMOVE SCREW TO ADJUST SECURE CONTROL LEVER WITH SCREW AFTER ADJUSTMENT Figure 4.40 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 33: Replacement Parts

    C. Loosen and remove the nut for the right angle connector Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 34 1/2" diameter collar and the inner ring. NOTE: This inner ring must be returned to its correct ori- entation with the 10-1/2" collar for proper fan operation. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 35 3 ft. 914 mm 40 ft. 12.1 m 4 ft. 1.2 m 50 ft. 15.2 m = 50 ft. (15.2 m) Maximum Figure 4.48 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 36 3 ft. 914 mm 30 ft. 9.1 m 4 ft. 1.2 m 40 ft. 12.1 m = 40 ft. (12.1 m) Maximum INSTALLED HORIZONTALLY Figure 4.49 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 37 914 mm 25 ft. 7.6 m 4 ft. 1.2 m 30 ft. 9.1 m Total V + Total H = 30 ft. (9.1 m) Maximum Figure 4.50 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 38 (Total V + Total H) of 28 ft. 34 ft. - (3 ft vertical drop x 2*) = 28 ft. Figure 4.51 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 39: Vent Clearances And Framing

    * Shows center of vent framing hole for top venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 5.2 Wall Penetration Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 40: Ceiling Firestop/Floor Penetration Framing

    BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 41: Install Attic Insulation Shield

    • Bend all tabs inward 90º around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 42: Appliance Preparation

    Remove all six screws and gently lift the panel off the appliance avoiding contact with the non-combustible board if possible. BOTTOM PANEL SCREW LOCATIONS Figure 6.1 Location of Fiberglass Rope Ring Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 43: Securing And Leveling The Appliance

    GRILLE PANEL DUCT COLLAR ASSEMBLY POSSIBLE LOCATIONS FOR VENT TERMINATION OF ACTIVE CONVECTION TECHNOLOGY TERMINATION INTO INTERIOR ROOM Figure 6.2 Proper Positioning, Leveling And Securing Of An Appliance Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 44: Active Convection Technology

    (INCLUDED WITH FLEX DUCT) 4 INCH CONVECTION 4 INCH FLEX DUCT AIR DUCT DETAIL A FAN BRACKET ASSEMBLY Figure 6.5 Active Convection Technology Duct Venting Specifi cations. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 45: Venting And Chimneys

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 INCORRECT in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. Figure 7.4 Seams Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 46: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 47: Disassemble Vent Sections

    Figure 7.10. • Pull carefully to separate the pieces of pipe. Figure 7.9 Rotate Seams for Disassembly Figure 7.10 Align and Disassemble Vent Sections Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 48: Vertical Termination Requirements

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 7.12. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 49: Horizontal Termination Requirements

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be fi eld constructed. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 50 1-1/2 IN. (38 MM) MIN. HEAT SHIELD OVERLAP WALL SHIELD FIRESTOP SLIP SECTION CAN BE EXTENDED INNER VENT SHEATHING OUTER VENT INTERIOR EXTERIOR Figure 7.15 Venting Through the Wall Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 51: Electrical Information

    Wiring for optional Hearth & Home Technologies ap- proved accessories should be done at initial installation to avoid reconstruction. Follow instructions that come with those accessories. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 52: Wiring Requirements

    HI LIMIT SWITCHES GROUND TO GREEN GREEN FIREPLACE CHASSIS JUMPER JUMPER JUMPER VALVE ORANGE ORANGE (Wire colors subject to change) Figure 8.2 RED60 IntelliFire Plus Wiring Diagram Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 53 Figure 8.5 Controls Location Diagram FAN ASSEMBLY FAN ASSEMBLY JUNCTION BOX JUNCTION BOX Figure 8.3 Valve Cavity (Lower Access Panel Removed) MODULE MODULE THERMODISC THERMODISC VALVE VALVE Figure 8.4 Valve Cavity Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 54 HIGH LIMIT SWITCH BLACK AXIAL FAN NOTE: Use threaded nut to BLOWER secure accessory cable to power vent. JUMPER WIRE WHITE Figure 8.6 Internal Wiring for PVI-DVP Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 55: Optional Led Lighting Circuit

    JUNCTION BOX GREEN BLUE YEL/ORG/GRN WHITE/CLEAR NOTE: Harness wire colors are subject to change without YEL/ORG YELLOW notice. ORG/GRN PURPLE YEL/GRN LIGHT BLUE Figure 8.7 LED Wiring Diagram Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 56: Active Convection Blower Replacement

    fi rebox opening. See Figure 8.14. Figure 8.10 Lifting Base Pan Up and Out. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 57 Remove blower and attached mounting bracket from the appliance. See Figure 8.16. Figure 8.18 Removal of Mounting Bracket from Blower Figure 8.16 Blower Removal Through Hole in Firebox Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 58 11. Connect electrical cord to the junction box. fan points toward the interior of the appliance. Arrows are highlighted by white boxes in Figure 8.20. Figure 8.20. Arrow Indicates Direction of Air Flow Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 59: Gas Information

    1. Remove the glass rock media or the porcelain from the • Close the manual shutoff valve BEFORE pressure testing gas line at test pressures interior fi rebox. equal to or less than 1/2 psig. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 60: Gas Connection

    • In CANADA: Reduce burner orifi ce 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility. GAS SHUT OFF VALVE GAS SHUT OFF VALVE Figure 9.4 Gas Fitting Access Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 61: Air Shutter Setting

    FULL GRANITE KIT .16 in. 1/4 in. LIGHT & MEDIA KIT .06 in. 1/4 in. FULL PORCELAIN KIT .16 in. 1/4 in. SHEET METAL .16 in. 1/4 in. REFRACTORY Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 62: Finishing

    Installation details associated with the Inside an Vertical Tube Furnace at 750 ºC and UL763 shall be Overlap Fit methods are discussed in this section. considered non-combustible materials. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 63 Specifi c requirements for each method if installation are described on the following pages of this section. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 64 FACTORY-INSTALLED combustible materials. 1 IN. NON-COMBUSTIBLE BOARD STANDARD DECORATIVE FRONT SHOWN 0-1-1/4 IN. THICK DRYWALL OR EQUIVALENT = AIR SPACE Figure 10.4 Overlap Fit Method Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 65: Mantel And Wall Projections

    Note: All TO CEILING measurements in inches. MAX. MIN. MEASUREMENTS FROM TOP EDGE OF THE FIRESCREEN DOOR ASSEMBLY Figure 10.7 Minimum Vertical and Maximum Horizontal Dimensions of Non-Combustibles Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 66: Mesh Fronts

    (INSIDE FIT METHOD) Figure 10.9 Noncombustible Surface Finishing Material 0-4 Inches Thick-Inside Fit Method MESH BRACKETS MESH FRAME ASSEMBLY HANGING TABS MESH FRAME ASSEMBLY Figure 10.10 Mesh Front Installation Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 67: Appliance Setup

    WARNING! Risk of Fire and Electric Shock! Use ONLY Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 68: Rock Media Instructions

    3. Figure 2 shows an outline of the burner tracks and the area in front of the pilot assembly. No rock media may be placed in the outlined area. Continue Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 69 This step may only be done when the fi replace is Fireplace will not function properly. Gas leak may occur. not activated and the glass is cool. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 70: Porcelain Instructions

    (4) Inside Base Mesh. See Figure 8. Figure 6. Front Inside Base Piece. Tools Required Cordless Drill 1/4 inch hex head driver tip Flat Blade Screwdriver Figure 7. Outside Front Trim Base Piece. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 71 Figure 9. Fastening Angle Tab to Secure Inner Back Panel. Figure 12. Positioning Porcelain Access Panel. GLASS ASSEMBLY ACCESS PANEL Figure 10. Fastening Angle Tab to Secure Inner Side Panel. Figure 13. Porcelain Trim Shelf Installed. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 72: Service Parts

    Panel Side (Qty 2 req) 2159-223 Outer Bottom Panel 2159-226 Bottom Front Panel 2159-224 Bottom Back Panel 2159-225 Back Panel 2159-222 Figure 16. Installing Outside Corner Trim Piece onto Clip. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 73 fi rebox. See Figure 6. Figure 3. Outside Corner Trim Pieces. 5. Bend the tabs mentioned on step 3 toward the porcelain panel. See Figure 8. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 74 • Do NOT use more than fi ve bags of media in the fi replace (when applicable). Fireplace will not function properly. Figure 9. Clip Location. Delayed ignition may occur. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 75: Granite Instructions

    (3) Back panel pieces 19-13/16 inches wide x 16-7/8 inches tall. See Figure 1. (2) Inner side wall pieces 10 inches wide x 16-7/8 inches tall. See Figure 2. Figure 3. Outside Corner Trim Pieces. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 76 Figure 7. Outside Front Trim Base. REAR BASE MESH GRANITE SUPPORT Figure 10. Removing Pilot Shield. FRONT BASE MESH GRANITE SUPPORT Figure 8. Middle and Outer Base Pan Granite Support Tabs. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 77 See Figure 16. The correct orientation for the front pieces is 19-3/8 inches wide by 4-5/8 inches deep. Figure 13. View of Back and Side Pieces Installed. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 78 14. Attach retaining tabs at the top by installing the sheet Panel Side (Qty 2 req) 2159-210 metal screws into the pilot holes located above the Back Panel (Qty 3 req) 2159-209 granite. See Figure 20. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 79 fi rebox. Continue with back middle piece and then back right side. Figure 4. Securing Tabs and Sheet Metal Screws. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 80 Use securing tabs to hold in place. Tabs attach at the top using sheet metal screws and pilot holes located above the granite. See Figure 9 and Figure 10. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 81: Sheet Metal Refractory Instructions

    fi rebox panel. These two gaps should be equal. See so the cutouts are in line with the outside edges of the Figure 4. glass frame. See Figure 7. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 82: Install The Mesh

    I. Install the Mesh A mesh front is included with the RED60 appliance. For installation instructions, see section 10.C. Figure 9. Installing Outside Corner Trim Piece onto Clip. Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 83: Reference Materials

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 12.1 DVP vent components Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 84 (203 mm) Shield 15-1/8 in. (384 mm) 12 in. Effective (305 mm) Length DVP-TRAP Horizontal Termination Cap DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC2 DVP-HPC1 Figure 12.2 DVP vent components Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 85 13-7/8 in. 9-1/2 in. (352 mm) (241 mm) 26 in. 660 mm 14 in. (356 mm) DVP-HSM-B DRC-RADIUS Extended Heat Shield Cap Shield Figure 12.3 DVP vent components Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 86 (For use with IPI and DSI appliances only.) NOTE: PVK-80 has specific wiring and venting requirements for use on the RED60 model. Refer to Section 7 for installation instructions. Figure 12.4 DVP vent components Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...
  • Page 87: Accessories

    Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. Printed in U.S.A. - Copyright 2013 Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13...

Table of Contents