D. Optional LED Lighting Circuit
For models with LED lighting option only.
LIGHT
CONTROL
YELLOW
ORANGE
GREEN
BLK
NOTE: The chart below show the colors produced
when light control is wired and orientated as shown
in this wiring diagram.
SWITCH TRIPPED
YELLOW
ORANGE
GREEN
YEL/ORG/GRN
YEL/ORG
ORG/GRN
YEL/GRN
Figure 12.6 LED Wiring Diagram
E. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
F. Junction Box Installation
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
1. Remove the one screw that secures the junction box to
the control tray panel.
2. Route the wire through the strain relief in the outer wrap
and down through the knockout located on top side of
the junction box. See Figure 12.7.
6 LEAD WALL CONTROL WIRE
APPLIANCE
ON/OFF
CONTROL
RED
BRN
COLOR PRODUCED
GREEN
RED
BLUE
WHITE/CLEAR
YELLOW
PURPLE
LIGHT BLUE
Heat & Glo • RED40, RED40ST • 2155-900 Rev. P • 10/12
LED LIGHTBAR
ASSEMBLY
2 1
RED
BRN
BRN
BRN
PLUG IN
WIRE ASSEMBLY
POWER SUPPLY
PLUG IN
I
S
IGNITION
PLUG IN
MODULE 3 VAC
NEUTRAL
HOT
3. Make the connection inside the junction box to the 120V
wire. Connect green to the ground nut, black to black,
and white to white.
4. To reattach the junction box, insert one end of the
junction box in the slot provided and securely screw the
other end of the junction box to the control tray panel.
Figure 12.7 Junction Box Detail
In the event that the junction box may need to be ac-
cessed or installed after fi nish methods have been ap-
plied, access is possible by removing the valve assembly
(See Figure 11.2).
L.E.D CONTROL
HARNESS
NOT USED FOR THIS MODEL
NOTE: Harness wire colors
are subject to change
without notice.
JUNCTION BOX
KNOCKOUT
KNOCKOUT
45