Ceiling Firestop/Floor Penetration Framing - Heat & Glo RED60 Installation Manual

Installation and appliance setup
Hide thumbs Also See for RED60:
Table of Contents

Advertisement

C. Ceiling Firestop/Floor Penetra-
tion Framing
A ceiling fi restop MUST be used between
fl oors and attics.
• DVP pipe only - Frame an opening 10 in.
by 10 in. (254 mm by 254 mm) whenever
the vent penetrates a ceiling/fl oor (see
Figure 5.3).
• Frame the area with the same sized lumber
as used in ceiling/fl oor joist.
• The ceiling fi restop may be installed above or
below the ceiling joists when installed with a
attic insulation shield. It must be under joists
between fl oors that are not insulated. Refer
to Figure 5.4.
• Secure with three fasteners on each side.
WARNING! Risk of Fire! DO NOT pack insu-
lation around the vent. Insulation must be kept
back from the pipe to prevent overheating.
40
Figure 5.3 Installing Ceiling Firestop
INSTALLED BELOW CEILING
Figure 5.4 Installing the Attic Shield
Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
INSTALL ATTIC INSULATION SHIELDS
BEFORE OR AFTER INSTALLATION OF VENT SYSTEM
3 FASTENERS
PER SIDE
CEILING FIRESTOP
ATTIC ABOVE
A
A
A
PIPE
10 in. (254 mm)
DVP
CEILING FIRESTOP
INSTALLED ABOVE CEILING